Sign In | Join Free | My burrillandco.com
Home > Radar Level Transmitter >

KLD800 Series FMCW 80GHz Non Contact Radar Level Transmitter For Liquid And Solid

    Buy cheap KLD800 Series FMCW 80GHz Non Contact Radar Level Transmitter For Liquid And Solid from wholesalers
     
    Buy cheap KLD800 Series FMCW 80GHz Non Contact Radar Level Transmitter For Liquid And Solid from wholesalers
    • Buy cheap KLD800 Series FMCW 80GHz Non Contact Radar Level Transmitter For Liquid And Solid from wholesalers
    • Buy cheap KLD800 Series FMCW 80GHz Non Contact Radar Level Transmitter For Liquid And Solid from wholesalers
    • Buy cheap KLD800 Series FMCW 80GHz Non Contact Radar Level Transmitter For Liquid And Solid from wholesalers

    KLD800 Series FMCW 80GHz Non Contact Radar Level Transmitter For Liquid And Solid

    Ask Lasest Price
    Brand Name : Kacise
    Model Number : KLD800 Series
    Certification : CE
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 1000pcs per month
    Delivery Time : 3-8 work days
    • Product Details
    • Company Profile

    KLD800 Series FMCW 80GHz Non Contact Radar Level Transmitter For Liquid And Solid

    KLD800 Series FM CW 80GHz Non-contact Corrosion Resistant Lens Antenna Radar Level Transmitter For Liquid and Solid

    Introduction

    80GHz frequency modulation radar level transmitter is also called frequency modulation continuous wave (FMCW) radar level transmitter, which is a higher frequency radar level gauge. Its main advantages are smaller emission angle, more concentrated energy, stronger echo signal, stronger penetration, and higher measurement accuracy. It can be applied to various occasions and is more stable than other radar products.

    It is effective in harsh conditions. Whether it is a toxic medium, or a corrosive medium, and whether it is a solid, liquid, dusty, or slurry medium, it can be measured.

    Feature

    1. More compact architecture, higher signal-to-noise ratio, and smaller blind spots.
    2. Higher measurement resolution and measurement accuracy.
    3. The narrowt 3° antenna beam angle, the interference in the installation environment will have less impact on the instrument, and the installation is more convenient.
    4. The wavelength is shorter and has better reflection characteristics on solid surfaces, so there is no need to use special universal flanges for aiming.

    5. Stable performance and long life. It can adapt to various environments and working conditions, and has strong corrosion resistance and anti-interference ability, and can work in various harsh working conditions.

    6. Accurate, safe and energy-saving: The chemical and mechanical properties of the materials used in radar level gauges are quite stable, and the materials can be recycled, which is extremely environmentally friendly.

    7. Maintenance-free and highly reliable: Microwaves are almost immune to interference and do not directly contact the measurement medium, so they can be used in almost all occasions, such as vacuum measurement, liquid level measurement or material level measurement, etc. Due to the use of advanced materials, it is durable to extremely complex chemical and physical conditions, and it can provide accurate, reliable, long-term stable analog or digital level signals.



    Specification
    KLD801Medium: liquid, non-corrosive
    Measuring range: 0.05m~10/20/30/60/100m
    Process connection: G1½A / 1½NPT thread / flange ≥ DN40
    Process temperature: -40~80℃
    Process pressure: -0.1~0.3 MPa
    Antenna size: 32mm lens antenna
    Antenna material: PTFE
    Accuracy: ±2mm
    Protection class: IP67
    Center frequency: 80GHz
    Launch angle: 3°
    Power supply: Two-wire /DC24V
    Four-wire system/DC12~24V
    Four-wire system/AC220V
    Casing: aluminum/plastic/stainless steel
    Signal output: two-wire /4...20mA/HART protocol
    Four-wire system: 4...20mA/ RS485 Modbus
    KLD802Medium: non-corrosive liquid, slightly corrosive liquid
    Measuring range: 0.1m~10/20/30/60/100m
    Process connection: flange ≥ DN80
    Process temperature: -40~110℃
    Process pressure: -0.1~1.6MPa
    Antenna size: 32mm lens antenna
    Antenna material: PTFE
    Accuracy: ±2mm (range below 35m)
    ±5mm (range between 35m and 100m)
    Protection class: IP67
    Center frequency: 80GHz
    Launch angle: 3°
    Power supply: two-wire /DC24V
    four-wire /DC12~24V
    four-wire /AC220V
    Casing: aluminum/stainless steel
    Signal output: two-wire /4...20mA/HART protocol
    four-wire / 4...20mA/ RS485 Modbus
    KLD803Medium: strong corrosive liquid, steam, foam
    Measuring range: 0.1m~10/20/30/60/100m
    Process connection: flange ≥ DN50
    Process temperature: -40~130℃
    Process pressure: -0.1~2.5MPa
    Antenna size: 34mm lens antenna (according to flange size)
    Antenna material: PTFE
    Accuracy: ±2mm (range below 35m)
    ±5mm (range between 35m and 100m)
    Protection class: IP67
    Center frequency: 80GHz
    Launch angle: 3°
    Power supply: two-wire /DC24V
    four-wire /DC12~24V
    four-wire /AC220V
    Casing: aluminum/stainless steel
    Signal output: two-wire /4...20mA/HART protocol
    four-wire 4...20mA/ RS485 Modbus
    KLD804Medium: strong corrosive liquid, steam, foam
    Measuring range: 0.1m~10/20/30/60/100m
    Process connection: flange ≥ DN50
    Process temperature: -40~130℃
    Process pressure: -0.1~1.0MPa
    Antenna size: 76mm lens antenna
    Antenna material: PTFE
    Accuracy: ±2mm
    Protection class: IP67
    Center frequency: 80GHz
    Launch angle: 2°
    Power supply: two-wire /DC24V
    four-wire /DC12~24V
    four-wire /AC220V
    Casing: aluminum/plastic/stainless steel
    Signal output: two-wire /4...20mA/HART protocol
    four-wire 4...20mA/ RS485 Modbus
    KLD805Medium: strong corrosive liquid, steam, foam,
    high temperature. and high pressure
    Measuring range: 0.1m~10/20/30/60/100m
    Process connection: flange ≥ DN80
    Process temperature: -40~200℃
    Process pressure: -0.1~2.5MPa
    Antenna size: 76mm lens antenna (according to flange size)
    Antenna material: PTFE/overall filling
    Accuracy: ±2mm
    Protection class: IP67
    Center frequency: 80GHz
    Launch angle: 3°
    Power supply: two-wire /DC24V
    four-wire /DC12~24V
    four-wire /AC220V
    Casing: aluminum / plastic / stainless steel
    Signal output: two-wire /4...20mA/HART protocol
    four-wire 4...20mA/ RS485 Modbus
    KLD806Medium: solid, storage container, process container,
    strong dust application
    Measuring range: 0.3m~10/20/30/60/100m
    Process connection: flange ≥ DN100
    Process temperature: -40~110℃
    Process pressure: -0.1~0.3MPa
    Antenna size: 76mm lens antenna (purge optional)
    Antenna material: PTFE
    Accuracy: ±5mm
    Protection class: IP67
    Center frequency: 80GHz
    Launch angle: 3°
    Power supply: two-wire /DC24V
    four-wire /DC12~24V
    four-wire /AC220V
    Casing: aluminum/plastic/stainless steel
    Signal output: two-wire /4...20mA/HART protocol
    four-wire 4...20mA/ RS485 Modbus

    KWL800 water level sensor

    Transmit Frequency76GHz~81GHz
    Measuring Range0.1 m ~ 65m
    Measurement Accuracy±1mm
    Beam Angle
    Power Supply Range9~36 VDC
    Communication MethodRS485
    Operating Temperature-40~85℃
    Shell MaterialPP
    Antenna TypeLens antenna
    Recommended Cable7*0.3mm²
    ProtectionIP68
    Installation MethodBracket


    Installation Method

    Thread installation (KLD801)


    Flange installation
    When using flange installation, the minimum distance between the instrument and the tank
    wall should be 200mm.
    ① datum plane
    ② vessel center or axis of symmetry



    Hoisting Installation



    Quality KLD800 Series FMCW 80GHz Non Contact Radar Level Transmitter For Liquid And Solid for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message: