Sign In | Join Free | My burrillandco.com
Home > Water Quality Sensor >

KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen

    Buy cheap KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen from wholesalers
     
    Buy cheap KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen from wholesalers
    • Buy cheap KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen from wholesalers
    • Buy cheap KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen from wholesalers

    KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen

    Ask Lasest Price
    Brand Name : kacise
    Model Number : KFDO310
    Certification : CE
    Price : $0-$2000
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 100
    Delivery Time : 3-10days
    • Product Details
    • Company Profile

    KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen

    1.Principle

    KFDO310 integrated on-line fluorescence dissolved oxygen sensor is designed and made based on the quenching principle of excited fluorescence of specific substances in physics. The blue light from the light-emitting diode illuminates the fluorescent material on the inner surface of the fluorescent cap. The fluorescent material on the inner surface is excited and emits red light. By detecting the phase difference between the red light and the blue light, and comparing it with the internal calibration value, the concentration of oxygen molecule can be calculated, and the final value can be output by temperature automatic compensation.

    2.Feature

    No electrolytes, no polarization

    No need to consume oxygen, not affected by the flow rate

    Built-in temperature sensor, automatic temperature compensation

    Free from chemicals like sulfides

    Small drift, fast response, more accurate measurement

    Maintenance-free, long service life, lower use cost

    Fluorescent caps are easy to replace

    RS-485 interface, Modbus-RTU protocol

    3.Technical Specifications

    Model numberKFDO310
    Measuring principlefluorescence
    Range0ー20 mg/L (0ー200% saturation, 25 °C)
    Resolution0.01 mg/l, 0.1 °C
    Precision± 2% f.s. , ± 0.5 °C
    Temperature compensationAutomatic temperature compensation (PT1000)
    Output modeRS-485 bus, Modbus-RTU protocol
    Working conditions0ー45 °C, < 0.2 mpa
    Storage temperature- 5 ~ 65 °C
    Installation modeImmersion mounting
    Cable length5 meters, other length can be customized
    Power consumption< 0.05 W
    Power supply12 ~ 24 VDC ± 10%
    Protection levelIP68
    CalibrationTwo-point calibration
    Fluorescent cap lifeGuaranteed Use for one year (under normal use)
    Material for sensor housingPom and 316L stainless steel

    4.Dimensional Drawing



    5.Installation and Electrical Connection

    Installs

    The temperature sensing part should be immersed below the liquid surface to avoid collision with the film head surface. The head part of the membrane should be free from sediment.


    What Affects Oxygen Solubility?


    Dissolved oxygen concentrations decrease as temperature increases

    Two bodies of water that are both 100% air-saturated do not necessarily have the same concentration of dissolved oxygen. The actual amount of dissolved oxygen (in mg/L) will vary depending on temperature, pressure, and salinity.

    First, the solubility of oxygen decreases as temperature increases ¹. This means that warmer surface water requires less dissolved oxygen to reach 100% air saturation than does deeper, cooler water. For example, at sea level (1 atm or 760 mmHg) and 4°C (39°F), 100% air-saturated water would hold 10.92 mg/L of dissolved oxygen. ³ but if the temperature were raised to room temperature, 21°C (70°F), there would only be 8.68 mg/L DO at 100% air saturation.

    Second dissolved oxygen decreases exponentially as salt levels increase ¹. That is why, at the same pressure and temperature, saltwater holds about 20% less dissolved oxygen than freshwater.


    Quality KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)