    RTU Protocol Water Turbidity Sensor For Monitoring Red Algae

    KBG602 Online Blue Green Algae Sensor Support RS-485 Modbus/RTU Protocol Monitoring Red Algae

    1.Working Principle

    The blue green algae sensor utilizes the characteristic that the blue green algae has an absorption peak and an emission peak in the spectrum. The spectral absorption peak of the blue green algae emits monochromatic light to the water, and the blue green algae in the water absorbs the energy of the monochromatic light, releasing another wavelength. The monochromatic light of the emission peak, the light intensity emitted by the blue green algae is proportional to the content of blue green algae in the water.

    2.Feature

    • Monitoring the concentration of micro algae in the ocean harbor
    • Monitoring green algae and blue algae such as rivers and lakes
    • Monitoring red algae
    • Determination of green algae concentration in the treatment of green algae cultivation equipment
    • Support RS-485 (Modbus/RTU protocol)
    • Convenient, fast, stable and easy to maintain

    3.Technical Specifications

    ItemValue
    Measuring range0—300.0 K cells/ml
    Resolution0.1 K cells/ml(100 cells/ml)
    Accuracy±3%
    CalibrationTwo-point calibration
    Protection gradeIP68
    Deepest depthUnderwater 20 meters
    Storage temperature-15~65℃
    Sensor interfaceRS-485(Modbus/RTU)
    Power information12~24 V DC ±10%
    Power consumption<0.3 W@12 V
    Cable length5 meters, other lengths can be customized
    Shell materialPVC



    ItemValue
    Conditional requirements

    The distribution of blue green algae in water is uneven, and it is recommended to monitor more;
    The water turbidity is less than 50 NTU.


    4.Dimensional Drawing
















    5. Installation and Electrical Connection
    5.1 Installation



    Installation distance requirement: keep more than 5 cm with the side wall and 20 cm or more with the bottom.

    5.2 Electrical Connection

    a) Red line - power cord (12 ~ 24 V DC)
    b) Black line - ground (GND)
    c) Blue line - 485 A
    d) white line - 485 B
    e) bare wire - shielded wire
    After wiring is completed, it should be carefully checked to avoid incorrect connections before powering up.

    Cable specification: Considering that the cable is immersed in water (including sea water) for a long time or exposed to the air, the cable has certain corrosion resistance. The outer diameter of the cable is Φ6 mm and all interfaces are waterproof.

    6 Maintenance

    6.1 Maintenance Procedures and Methods

    6.1.1 Maintenance Schedule

    The cleanliness of the measurement window is very important to maintain accurate readings.

    Calibrate the sensor (if required by the competent authority) according to the maintenance schedule required by the competent authority

    Maintenance taskRecommended maintenance frequency
    Calibrate the sensor (if required by the competent authority)According to the maintenance schedule required by the competent authority

    6.1.2 Maintenance Methods

    • Sensor outer surface: Clean the outer surface of the sensor with tap water. If there is still debris left, wipe it with a soft, damp cloth. For some stubborn dirt, add some household washing liquid to the tap water to clean it.
    • Check the cable of the sensor: the cable should not be tightened during normal operation. Otherwise, the internal cable of the cable may be broken and the sensor may not work normally.
    • lCheck the sensor's measurement window for dirt.

    6.1.3 Precautions
    The probe contains sensitive optical and electronic components. Make sure the probe is not subject to severe mechanical shock. There are no parts inside the probe that require user maintenance.

    6.2 Sensor Calibration

    a) Zero calibration: Take a proper amount of distilled water in a large bucket and place the sensor vertically in the solution. The front end of the sensor is at least 20 cm away from the bottom of the beaker. After 3 to 5 minutes, the value is stabilized and the zero point is calibrated. The instructions refer to the appendix.
    b) Slope calibration: Place the sensor probe in the standard solution. The front end of the sensor is at least 20cm away from the bottom of the beaker. After 3 to 5 minutes, the slope is calibrated after the value is stable. The instructions refer to the appendix.

    6.3 Frequently Asked Questions

    ErrorPossible ReasonSolution
    The operation interface cannot be connected or the measurement result is not displayed.The measured value is too high, too low or the value is continuously unstable

    Reconnect controller and cable

    Cable failurePlease contact us
    The measured value is too high, too low or the value is continuously unstableThe sensor window is attached by a foreign objectCleaning the sensor window surface

    7.Quality and Service

    7.1 Quality Assurance

    • The quality inspection department has standardized inspection procedures, advanced and perfect

    testing equipment and means, and strictly in accordance with the regulations, to do 72-hour aging test and stability test on the product, and not to allow one unqualified product to leave the factory.

    • The receiving party directly returns the product batch with a failure rate of 2%, and all the costs incurred are borne by the supplier. The reference standard refers to the product description provided by the supplier.
    • Guarantee the quantity of goods and the speed of shipment.

    7.2 Accessories Spare and Parts

    This product includes:

    • 1 sensor
    • Calibration powder 3 packs
    • 1 copy of the manual
    • 1 certificate

    7.3 After-sales Service Commitment

    The company provides local after-sales service within one year from the date of sale, but does not include damage caused by improper use. If repair or adjustment is required, please return it, but the shipping cost must be conceited. Damaged on the way, the company will repair the damage of the instrument for free.

    Contact Us

    Website www.kacise.com
    Phone +86-17719566736
    Email sales@kacise.com
    Location Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China



































    Quality RTU Protocol Water Turbidity Sensor For Monitoring Red Algae for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)