    Ask Lasest Price
    Brand Name : kacise
    Model Number : KBU601
    Certification : CE,FDA
    Price : $0-$2000
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 100
    Delivery Time : 10-15 days
    • Product Details
    • Company Profile

    KLT900 Menu Driven Water Turbidity Sensor Lightning Proof

    KLT900 online turbidity meter turbidity sensor water quality stainless steel probe Lightning proof

    Production Introduction


    Outlines that the TSS turbidity/suspended matter concentration meter is an on-line analytical instrument designed for measuring turbidity or suspended matter in municipal sewage or industrial wastewater treatment.The TSS turbidity/suspended matter concentration meter consists of a transmitter and a sensor.The sensor can be easily installed in a pool or in a natural water body.The TSS turbidity/suspended matter concentration meter automatically compensates for the interference caused by pollution.Bidirectional digital communication between the transducer and the transducer prevents signal attenuation and allows greater distance between the transducer and the transmitter.


    Measuring principle


    TSS turbidity/suspended matter concentration meter work principle as shown in figure 1-1, sensor transmitter to send the red outside light in transit after being measured the absorption and scattering of content, part of the scattering light to 135°direction of detector, part of the scattering light detector to 90°direction.The light intensity in the direction of 135°and 90°is related to the turbidity of the measured sewage to a certain extent, and the TURBidity of TSS is precisely based on this principle for measurement.


    Turbidity meter size structure diagram


    host size



    sensor size


    Turbidity meter technical parameters


    Performancevalue
    SystemMenu-driven software, with multi-point calibration function and binding programming, can set the measurement range, relay and current output;
    SupplyAC220V (min85V- max265V) 50/60Hz
    Maximum power consumed15 VA
    Fuse2A /220VAC
    Range0~4000 NTU
    Measurement UnitNTU and mg/L are available.
    Resolution Rate0.1NTU
    Accuracy2% of the measured value, within 10NTU the error is not greater than 1NTU.
    DisplayThe display screen is 192 × 64 pixels, which can display turbidity measurement value, current time, historical trend line, etc.
    Principleinfrared light scattering 90° and 135°
    Output1 channel 4~20mA current signal isolation output, maximum load 750 ohms; 1-channel RS232 and 1-channel RS485 digital output (optional); 3 alarm signal relays, capacity 220 VAC/ 2 A, output can be set by the user;
    Host:MaterialABS+PC
    Host:Protection LevelIP65
    Sensor Material316L stainless steel
    Cable LengthDedicated shield cable, standard 10 meters (extendable)
    Operating Temperature0-50℃
    Pressure0.6MPa
    CalibrateIt has been calibrated before delivery and no calibration is needed on site

    Ordering Information Selection Table

    Ordering Information Selection Table
    KXTX00PH/ORP analyzer
    Power supplyDC24V
    AC220V
    Cable length5m
    10m
    15m
    20m
    Temperature compensationSensor without temperature compensation
    Sensor with temperature compensation
    Signal outputOnly 4-20mA
    Only 485
    Also with 4-20mA , 485 signal output
    Special custom signal
    KLT500-DC24V--5m-Sensor without temperature compensation-Only 485Low Turbidity host, with DC 24V adapter, cable between host and sensor,The cable length is 5 meters, the sensor is equipped without temperature compensation, and is only 485 communication.


    Contact us
    Website: www.kacise.com
    Phone: +86-17719566736
    Email: sales@kacise.com
    Location: Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China



    Abbreviations table
    NTU
    The unit of turbidity is "degree", which is equivalent to the degree of turbidity produced by 1L water containing 1mg SiO2 (or white clay, diatomite), which is 1 degree, or Jackson.Turbidity unit is JTU, 1JTU=1mg/L white clay suspension.
    The turbidity shown by modern instruments is the unit of scattering turbidity NTU, also known as TU.1NTU= 1JTU.
    Recently, it is considered internationally that the standard of turbidity prepared with ullotropin-hydrazine sulfate has good reproducibility and is chosen as the uniform standard of FTU.1FTU=1JTU.

    Quality KLT900 Menu Driven Water Turbidity Sensor Lightning Proof for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)