Sign In | Join Free | My burrillandco.com
Home > Vortex Flow Meter >

LC Series Oval Gear Type Flow Meter Oval Positive Displacement Flow Meter With Strainer

    Buy cheap LC Series Oval Gear Type Flow Meter Oval Positive Displacement Flow Meter With Strainer from wholesalers
     
    Buy cheap LC Series Oval Gear Type Flow Meter Oval Positive Displacement Flow Meter With Strainer from wholesalers
    • Buy cheap LC Series Oval Gear Type Flow Meter Oval Positive Displacement Flow Meter With Strainer from wholesalers
    • Buy cheap LC Series Oval Gear Type Flow Meter Oval Positive Displacement Flow Meter With Strainer from wholesalers

    LC Series Oval Gear Type Flow Meter Oval Positive Displacement Flow Meter With Strainer

    Ask Lasest Price
    Brand Name : Kacise
    Price :
    Payment Terms : L/C, T/T, Western Union, MoneyGram, D/A, D/P
    Supply Ability : 10000pcs/month
    Delivery Time : 5-8 working days
    Model Number : LC
    • Product Details
    • Company Profile

    LC Series Oval Gear Type Flow Meter Oval Positive Displacement Flow Meter With Strainer

    Series Oval Gear Flow Meter Oval positive displacement flow meter with strainer for bitumen
    Introduction

    Oval gear flowmeters are highly precise instruments used for the continuous measurement of liquid flow in pipelines. They offer various advantages, including a wide measuring range, low pressure loss, adaptability to high viscosity, the capability to measure high-temperature liquids, convenient calibration, and easy installation. As representative products in the positive displacement flowmeter category, oval gear flowmeters play a crucial role in accurately measuring liquid flows.


    The LC series oval gear flowmeter is equipped with an on-site pointer display and a word wheel cumulative counting device. This configuration allows for the direct display of the cumulative flow of liquid passing through the pipeline. Specifically designed for metering refined oil products, it is extensively employed in industries such as petroleum, chemicals, chemical fiber, transportation, commerce, food, medicine, health, and more. It facilitates precise flow measurement of non-corrosive media in diverse applications.


    Usage
    LC-A type cast iron oval gear flow meter, widely used in all kinds of oil products and for the measurement of the cast iron material not corrosion liquid medium.
    LC-E type cast steel oval gear flow meter, Used for high pressure, low corrosive medium measurement.
    LC-Q type cast iron oval gear flow meter, The rotor for aluminum alloy, is suitable for low viscosity, low corrosion, such as gasoline, etc.) the measurement of liquid medium.
    LC-B, C type stainless steel oval gear flow meter, widely used in strong corrosive liquid medium, such as acid, alkali, salt and organic compounds, the measurement of liquid medium.
    LC-L type Aluminum alloy oval gear flow meter, is a small oval gear flow meter, widely used in low corrosive liquid medium, such as water, such as the measurement of liquid medium.

    Materials of main parts and the nominal operating pressure

    Shell and covercover plateoval wheelRotary shaftbushingNominal pressure(MPa)
    LC-ACast steelCast iron

    Cast iron,Stainless steel

    Alloy aluminum,

    engineering material

    Stainless steelBronze(with oil) or rolling bearing1.6
    LC-ECast steelCast iron

    Under DN50 6.3

    DN80-100 4.0 6.3

    DN150-200 2.5

    LC-B,CStainless steelStainless steelStainless steelgraphite,rolling bearing1.6,2.5

    Notes:1. 0Cr18Ni12Mo2Ti for type LC-C; 0Cr18Ni9Ti for type LC-B.

    2. Flange is convex under 2.5MPa ,and roughness at 6.3 MPa;and both of the above at 4.0 MPa.

    2. Accuracy class class 0.5,class 0.2

    3. Operating temperature: series LC-A(-20℃~+60℃),series LC-B,E,L(-41℃~+60℃)

    60℃~200℃(with high temp. radiator installed)

    4 Explosion-proof mark: ExiaⅡCT5, dⅡBT4

    5. Flow range: unit: m3/h

    TypeDNViscosity (mPa. s)

    <0.3

      0.3~0.8

        0.8~22~200

        200~1000


        1000~2000


        LC-10

        10



        0.2-0.5


        0.08-0.50.08-0.5

        0.05-0.5


        0.06-0.3

        0.03-0.3


        0.03-0.2


        LC-15

        15



        0.75-1.

        5

        0.3-1.50.3-1.5

        0.15-1.5

        0.3-3

        0.2-1.0

        0.1-1.05


        0.07-0.75


        LC-20

        20



        1.5-3


        1-30.5-30.5-3

        0.3-3

        1.5-15

        0.4-2.1

        0.2-2.1


        0.15-1.5


        LC-25

        25


        4-6


        3-6


        2-61-61-6

        0.6-6

        1.56-15

        0.8-4.2

        0.4-4.2


        0.3-3


        LC-40

        40


        9-15


        7.5-15


        5-152.5-152.5-15

        1.5-15


        2.1-10.5

        1.0-10.5


        0.7-7.5


        LC-50

        50


        10-24


        8-24


        8-244.8-244.8-24

        2.4-24


        2.4-16.8

        1.6-16.8


        1.2-12


        LC-B40,5040,508-206-206-204-204-202-202.8-141.4-141.0-10
        LC--65

        65


        27-40


        20-40


        15-408-408-40

        4-40


        5.6-28

        2.8-28


        2-20


        LC-80

        80


        40-60


        30-60


        20-6012-6012-60

        6-60


        8.4-42

        4.2-42


        3-30


        LC-100

        100


        67-100


        50-100


        34-10020-10020-100

        10-100


        14-70

        6-70


        5-50


        LC-150

        150


        127-190

        95-190


        64-19038-19038-190

        19-190


        26.6-133

        13.3-133


        9.5-95


        LC-200200227-340

        170-340


        114-34056-34056-340

        34-340


        47.6-238

        23.8-238


        17-170


        Accuracy class0.50.50.20.50.20.50.20.50.5

        Note: If the temperature of the metered liquid is higher than 80℃. the maximum flow fate will be 90% of the primary flow, and the minimum will be 120%.


        Installation and Operation

        • A strainer should be installed in front of the meter, and be sure that the arrows on the casting of the meter and the strainer pointing the same direction of the liquid flow.
        • If the metered media contains gas, a gas separator should be installed in front of the meter.
        • Whether the pipe line is vertically or horizontally installed, the wheel’s shaft of the meter must be fixed horizontal, that is, the dial is vertical to the surface.
        • While the meter is installed properly, the counter may be turned 180°or 90°for easy reading.
        • Prior to the installation of the new meter, first push the oval wheels from the outlet for several times with a bamboo rod, if the wheels don’t move, they can be immersed in the petrol to prevent from deposits in the meter after the factory’s inspection.
        • A throttle valve must be fixed at the inlet of the meter, an on-off valve at the outlet, which must be slowly activated to prevent from a sudden impact, reverse flow, and water hammer.
        • It is forbidden to clean the meter with steam.
        • For the continuous operated departments, a by-pass should be mounted.
        • Prior to the installation of the meter, the pipe line must be thoroughly cleaned,and at the time of cleaning use a straight pipeline in stead of the meter,to prevent impurity,welding residue from entering the meter.
        • It is forbidden to inspect the meter made of cast iron and cast steel using water.
        • During the operated of the meter the flow rate can’t exceed the flow marked on the mamelon plate. It is preferable to operate the meter at 50—80% of the max. flow.
        • If the metered media is causticity,stainless steel shall be selected.

        LC Series Oval Gear Type Flow Meter Oval Positive Displacement Flow Meter With Strainer


        Quality LC Series Oval Gear Type Flow Meter Oval Positive Displacement Flow Meter With Strainer for sale
        Inquiry Cart 0
        Send your message to this supplier
         
        *From:
        *To: Xi'an Kacise Optronics Co.,Ltd.
        *Subject:
        *Message:
        Characters Remaining: (0/3000)