    Ask Lasest Price
    Brand Name : KACISE
    Model Number : M18 KUS1000
    Certification : CE
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 1000 Piece/Pieces per Week negotiable
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    Ultrasonic Water Level Sensor RS232/485 4-20mA Output Fluid Level Meter 40KHZ Frequency IP67

    Ultrasonic tank water level sensor RS232/485 4-20mA Output Signal low cost price ultrasonic liquid level meter gauge


    1. Parameter

    General specifications

    Sensing range100... 1000 mm
    Adjustment range
    Unusable area0 ... 100 mm
    Standard target plate100 mm x 100 mm
    Transducer frequencyapprox.220 kHz
    Response delayapprox. 50 ms

    Indicators/operating means


    LED bluepower-on

    LED yellow

    indication of the switching state

    flashing: program function object detected


    LED red

    permanently red: Error Red,flashing:program function,object not detected

    Electrical specifications

    Operating voltage UB15 ... 30 V DC , ripple 10 %SS
    No-load supply current I0≤ 45 mA

    Input

    Input type1 TEACH-IN input

    operating range A1: -UB ... +1 V, operating range A2: +6 V ...

    +UB

    input impedance: > 4.7 kΩ ; TEACH-IN program pulse: ≥ 1 s

    Output

    Output type1 switch output E4, NPN NO/NC,programmable
    Rated operating current Ie200 mA , short-circuit/overload protected
    Default settingSwitching point A1:70mm Switching point A2: 800mm
    Voltage drop≤ 2.5 V
    Repeat accuracy≤1 %
    Switching frequency f≤ 13 Hz
    Range hysteresis H2 % of the set operating distance
    Temperature influence±1.5% of full-scale value

    Ambient conditions

    Ambient temperature-25…70℃(248...343K)
    Storage temperature-40…85℃(233...358K)

    Mechanical specifications

    ConnectionV1 connector(M12×1),4-pin
    Protection degreeIP67
    Material Housingbrass, nickel-plated
    Transducer

    epoxy resin/hollow glass sphere mixture;

    foam polyurethane, cover PBT

    2. Dimensions

    3. Electronic interface and signals definition


    4. Description of Sensor Functions

    Adjust the paramater

    The ultrasonic sensor is equipped with a switch output featuring two teachable switching points. To set these points, the supply voltage, either -UB or +UB, needs to be applied to the TEACH-IN input. During this process, LEDs provide feedback, indicating whether the sensor has successfully recognized the target. Switching point A1 is configured using -UB, while A2 is set with +UB. The sensor offers the flexibility of eight different output functions.


    It's important to note that the switching point and setting distance can only be adjusted after the power is turned on. The internal clock ensures that changes cannot be made after 5 minutes of power-on time. If there's a need to modify the switching point, the user must set the desired distance after restarting the power. This ensures a clear and controlled adjustment process for the sensor's configuration.


    TEACH-IN window mode, normally-open function

    - Set target to near switching point

    - TEACH-IN switching point A1 with - UB

    - Set target to far switching point

    - TEACH-IN switching point A2 with + UB

    TEACH-IN window mode, normally-closed function

    - Set target to far switching point

    - TEACH-IN switching point A2 with - UB

    - Set target to near switching point

    - TEACH-IN switching point A1 with + UB

    TEACH-IN switching point, normally-open function

    - Set target to near switching point

    - TEACH-IN switching point A1 with - UB

    - Cover sensor with hand or remove all objects

    from sensing range

    -TEACH-IN switching point A2 with + UB

    TEACH-IN switching point, normally-closed function

    - Cover sensor with hand or remove all

    objects from sensing range

    - TEACH-IN switching point A2 with - UB

    - Set target to near switching point

    - TEACH-IN switching point A1 with + UB

    TEAC-IN large hysteresis interval, normally-open mode

    - Set target to near switching point

    - TEACH-IN switching point A1 with + UB

    - Set target to far switching point

    - TEACH-IN switching point A2 with - UB

    TEAC-IN large hysteresis interval, normally-closed mode

    - Set target to far switching point

    - TEACH-IN switching point A2 with + UB

    - Set target to near switching point

    - TEACH-IN switching point A1 with - UB

    TEACH-IN detection of objects presence normally open mode

    - Cover sensor with hand or remove all objects from

    sensing range

    - TEACH-IN switching point A2 with - UB

    - Cover sensor with hand or remove all objects from

    sensing range

    - TEACH-IN switching point A2 with + UB

    TEACH-IN detection of objects presence normally closed mode

    - Cover sensor with hand or remove all objects from sensing range

    - TEACH-IN switching point A2 with +UB

    - Cover sensor with hand or remove all objects from sensing range

    - TEACH-IN switching point A2 with -UB

    Default setting of switching point

    A1=blind range,A2=nominal distance


    LED displays
    Displays in dependence on operating modeRed LEDYellow LED

    TEACH-IN switching point

    Object detected

    No object detected

    Object uncertain(TEACH-IN invalid)


    off flashes On


    flashes off

    off

    Normal operationoffSwitching state
    FaultonPrevious state

    5. Installation conditions


    If the sensor is installed at the environment temperature fall below 0℃,It should do well on the protective measures. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread.