Sign In | Join Free | My burrillandco.com
Home > Electromagnetic Flow Meter >

Large Diameter Range Electromagnetic Flow Meter For Electrically Conductive Fluids

    Buy cheap Large Diameter Range Electromagnetic Flow Meter For Electrically Conductive Fluids from wholesalers
     
    Buy cheap Large Diameter Range Electromagnetic Flow Meter For Electrically Conductive Fluids from wholesalers
    • Buy cheap Large Diameter Range Electromagnetic Flow Meter For Electrically Conductive Fluids from wholesalers
    • Buy cheap Large Diameter Range Electromagnetic Flow Meter For Electrically Conductive Fluids from wholesalers

    Large Diameter Range Electromagnetic Flow Meter For Electrically Conductive Fluids

    Ask Lasest Price
    Brand Name : Kacise
    Model Number : GXEFM2000
    Certification : certificate of explosion-proof, CE
    Price : Negotiable
    Payment Terms : L/C, D/A, T/T, D/P, Western Union, MoneyGram
    Supply Ability : 1000 Pieces per Week
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    Large Diameter Range Electromagnetic Flow Meter For Electrically Conductive Fluids

    Kacise GXEFM2000 High accuracy clamp on industrial water flow meter transducer for flow test electromagnetic flow meter


    Description


    1. Simple structures, firm, no movable parts and long operation life.(Guarantee in 1 years)

    2. No intercepting fluid parts, no pressure loss and fluid clogging.

    3. No mechanical inertia, quick response and good stability, application in automatic examination, adjustment & controlling.

    4. Measuring accuracy not influenced by physical parameters such as style, temperature, viscosity, density and pressure.


    Parameters


    Pipe diameterDN6~DN2600
    Accuracy0.3% (Option), 0.5%, 1.0% of F.S..
    RepeatabilityBelow 0.25%
    PowerAC: 220V, 50-60Hz; DC: +24V(Option)
    Output Signals4~20mA, Pulse, 0~5V
    Conduit connectionM20 * 1.5 Thread
    Communication InterfaceRS-232; RS-485; HART
    Operation Pressure1.0MPa, 1.6MPa, 4.0MPa, 16MPa (Special)
    Fluid Temperature-20°C~80°C, 80°C ~130°C, 130°C ~180°C Depending on Lining Material
    Ambient TemperatureSensor -40°C ~80°C. transducer -15°C ~50°C
    Ambient Humidity≤ 85%RH (at 20C)
    Cable Outlet SizeM20×1.5
    Power Supply220VAC±10%, 50-60Hz±1Hz, 24VDC±10%, Battery power (3-5years)
    Power Consumption≤ 15W
    Protection RatingsRemote type: sensor IP68, transducer IP65.
    MaterialsElectrode316L (stainless steel), Hastelloy C, Hastelloy B,Titanium, Tantalum, etc.
    LinerPTFE, Soft rubb er, Hard rubber, F46, FS, PUR.
    Measuring tubeSS 304, carbon steel
    FlangeCarbon Steal, SS304
    Ground ring316L (stainless steel), HC, Ti, Ta, Cu.
    Connection of Flange

    National Standard GB9119-88 (DIN2051, BS4504), JIS,ANSI. Screw.

    Tri-clamp for sanitary application

    Insertion type.

    EX-proof protectionExde ib ii BT2
    Quality control

    ISO9001-2008, CE


    Measuring system


    Measuring principleFaraday’s law
    Application rangeElectrically conductive fluids
    Measured Value
    Primary measured valueFlow velocity
    Secondary measured valueVolume flow

    Design


    FeaturesFully welded maintenance-free sensor
    Flange version with full bore flow tube
    Standard as well as higher pressure ratings
    Large diameter range from DN15~3000 with rugged liners approved for drinking water
    Industry specific insertion lengths
    Modular constructionThe measurement system consists of a flow Sensor and a signal converter. It is available as compact and as separate version
    Compact versionWith 511B converter: 110~240Vac Power
    With 521B converter: 18~36V DC Power
    With W800L/W800W: Battery Power
    Remote version

    In wall mount version with 211B converter

    (110~240Vac or 221B converter 18~36V DC

    With W800F converter: Battery Power
    Measurement range-12…+12m/s /-40...+40ft/s

    Measuring accuracy


    Reference conditionsFlow conditions similar to EN 29104
    Medium: water
    Electrical conductivity: ≥300μs/cm
    Temperature: +10~+30℃/+50~+80℉

    Inlet setion: ≥5DN
    Operating pressure: 1Bar/14.5psig
    Flow Meter AccuracyStandard: 0.5% of rate
    Optional: 0.2% of rate

    Operating conditions


    Temperature
    Process temperatureHard rubber liner: -5~+60℃
    Polypropylene liner: -5~+90℃
    PTEF liner: -5~+120℃
    Ambient temperatureStandard (with aluminum converter housing)

    -20~+60℃ (Protect electrics against self-heating

    with ambient temperature above 55℃

    Stroage temperature-20~70℃
    Pressure
    EN 1092-1DN2200~3000: PN2.5
    DN1200~2000: PN6
    DN200~1000: PN10
    DN65~150: PN16
    DN10~50: PN40
    Other pressure on request
    ISO insertion lengthOptional for DN15~600
    ASME B16.51~24”: 150lb RF
    Other pressure on request
    JISDN10~1000/ 2~40”: 10K
    Other pressure on request
    Pressure dropNegligible

    Fluid
    Physical conditionConductive liquids
    Electrical conductivity≥5μs/cm
    Permissible gas content (volume)≤5%
    Permissible solid content≤70%

    Installation conditions


    InstallationTake care that flow sensor is always fully filled
    For detailed information see chapter “Cautions for installation”
    Flow directionForward and reverse
    Arrow on flow sensor indicates positive flow direction
    Inlet run≥5 DN
    Outlet run≥2 DN

    Process connection


    Flange
    EN1092-1DN25~3000 in PN6~40
    ASME1~120” in 150 lb RF
    JIS25~1000 in 10~20k
    Design of gasket surfaceRF
    Other sizes or pressure ratings on request

    Company Information

    Xi'an Kacise is qualified with ISO 9001-2008, GJB 9001B-2009, CE, intrinsic safety explosion-proof and isolated safety explosion-proof certificates, etc. which ensure that our products comply with international standards.

    We have been specializing in manufacturing pressure, level and flow measuring instruments and related products for 10 years. Based on experienced technical and management personnel, through efforts of our entire staff, we have become a professional measuring instrument manufacturer and solution provider. And we are continuously trying to improve product quality.

    Currently, Kacise sensors have already been exported to America, Spain, Australia, Chile and 20 other countries and regions, and received many favorable feedbacks. Our overseas distributers are also increasing. We regard “reasonable prices, efficient production time and good after-sales service” as our tenet, and hope to cooperate with more customers for mutual development.

    Quality Large Diameter Range Electromagnetic Flow Meter For Electrically Conductive Fluids for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)