Sign In | Join Free | My burrillandco.com
Home > Fluid Level Meter >

MF30 Series Ultrasonic Distance Sensor 200mm - 6000mm Detection Range with NPN PNP Anolog Output

    Buy cheap MF30 Series Ultrasonic Distance Sensor 200mm - 6000mm Detection Range with NPN PNP Anolog Output from wholesalers
     
    Buy cheap MF30 Series Ultrasonic Distance Sensor 200mm - 6000mm Detection Range with NPN PNP Anolog Output from wholesalers
    • Buy cheap MF30 Series Ultrasonic Distance Sensor 200mm - 6000mm Detection Range with NPN PNP Anolog Output from wholesalers
    • Buy cheap MF30 Series Ultrasonic Distance Sensor 200mm - 6000mm Detection Range with NPN PNP Anolog Output from wholesalers

    MF30 Series Ultrasonic Distance Sensor 200mm - 6000mm Detection Range with NPN PNP Anolog Output

    Ask Lasest Price
    Brand Name : KACISE
    Model Number : KUS550
    Certification : CE
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 1000 Piece/Pieces per Week negotiable
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    MF30 Series Ultrasonic Distance Sensor 200mm - 6000mm Detection Range with NPN PNP Anolog Output

    MF30 Series Ultrasonic Distance Sensor 200mm - 6000mm Detection Range with NPN PNP Anolog Output

    1. Parameter

    General specifications

    M18
    Sensing range100... 1000 mm
    Adjustment range100….1000mm
    Unusable area0 ... 100 mm
    Standard target plate100 mm x 100 mm
    Transducer frequencyapprox.220 kHz
    Response delayapprox. 10 ms

    M30-type1
    Sensing range200... 2000 mm
    Adjustment range200….2000mm
    Unusable area0 ... 200 mm
    Standard target plate100 mm x 100 mm
    Transducer frequencyapprox.150 kHz
    Response delayapprox. 10 ms

    M30-type2
    Sensing range200... 3000 mm
    Adjustment range200….3000mm
    Unusable area0 ... 150 mm
    Standard target plate100 mm x 100 mm
    Transducer frequencyapprox.70 kHz
    Response delayapprox. 20 ms

    M30-type3
    Sensing range400... 6000 mm
    Adjustment range400….6000mm
    Unusable area0 ... 300 mm
    Standard target plate100 mm x 100 mm
    Transducer frequencyapprox.50 kHz
    Response delayapprox. 40 ms

    Indicators/operating means


    LED blue

    Flashing :program can be acted, this status

    The Blue led will flash around 5 minute after the sensor power on, indicate the sensor can be programed, and then the blue led will perpetually turn on. To indicate the power status.

    LED yellow

    indication of the switching state

    flashing: during program function object detected

    LED red

    Normal working: light on indicate error detected.

    Programing: flashing, echo lost, that means the sensor covered or no object in the fromt of the sensor,

    Electrical specifications


    Operating voltage UB13 ... 30 V DC , ripple 10 %SS
    No-load supply current I0≤ 45 mA

    Input

    Input type1 TEACH-IN input

    operating range A1: 0V/GND ... +1 V, operating range A2: +6 V ...

    +UB

    input impedance: > 4.7 kΩ ; TEACH-IN program pulse: ≥ 1 s

    Output


    Output type

    1 switch output E4, NPN NO/NC, programmable

    2 switch output E4, PNP NO/NC, programmable

    3 Analog 0-10V output E4 programmable.

    4 Analog 4-20mA output E4 programmable

    5 RS485 output E4 programmable.

    Rated operating current Ie200 mA , short-circuit/overload protected
    Default settingSwitching point A1:150mm Switching point A2: 1000mm
    Voltage drop≤ 2.5 V
    Repeat accuracy≤1 %
    Switching frequency f≤ 13 Hz(customized for high frequency version)
    Range hysteresis H5 % of the set operating distance
    Temperature influence±1.5% of full-scale value

    Ambient conditions


    Ambient temperature-25…70℃(248...343K)
    Storage temperature-40…85℃(233...358K)

    Mechanical specifications


    ConnectionV1 connector(M12×1),4-pin
    Protection degreeIP67
    Material Housingbrass, nickel-plated
    Transducer

    epoxy resin/hollow glass sphere mixture;

    foam polyurethane, cover PBT

    2. Dimensions

    3. Electronic interface and signals definition

    4. Description of Sensor Functions

    Adjusting the switching points and the analog output.

    The switch output type and analog output type sensor can be programed as the user want.

    There is 8 types of output functions can be programed.

    All the teach routine as follows,

    step 1 teach one point with the related teach in condition(High level voltage or GND). step 2 choose a different distance(not the same with step1) point and a different teach in condition(not same with the step1). The program routine must be finished during the blue led flashing, the default value will be efficient if the not.

    The ultrasonic sensor features a switch output with two teachable switching points. These are set by applying the supply voltage - UB or + UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs indicate whether the sensor has recognized the target during the TEACH-IN procedure. Switching point A1 is taught with - UB, A2 with +UB. Five different output functions can be set.

    1. Window mode normally-open and liner mode positive slope output function.

    2. Window mode normally-closed and liner mode negative slope output function.

    3. Single switching point, normally-open function.

    4. Single switching point, normally-closed function.

    5. Single switch point with hysteresis gap normally-open function.

    6. Single switch point with hysteresis gap normally-closed function.

    7. Detection of object presence-normal open function.

    8. Detection of object presence-closed open function.

    Switching point, Setting distance only after power on. The internal clock can assure can't be changed after 5 minutes after power on. If want to change the switching point, the user can only setting the request distance after power restart.

    For the RS485 output type.

    There is 2 kinds of working style,

    One for auto measure, the sensor will measure the distance or level repeatedly, and the measurement period can be set by the uart. The measure result can be fetched every time.

    The other style is power save mode when the sensor is sleep, until the sensor received the inquiry command with pre-code. Communication protocol is Modus-RTU.

    For example the measure result can be read by access the register 0x101 by Modbus protocol.

    For more information please contact us for the software engineering guide.


    LED displays
    Programming timeWorking time
    Red LEDON--Error accured
    OFFWorking wellWorking well
    Flash

    Doing the echo lost program,

    For Single switching point, program, or Detection of object.

    -----
    Yellow LEDON----Object detacted
    OFF------Echo lost
    Flash

    Teach in for the status ready,

    That means the sensor has locked the set distance for program

    -----
    Blue LEDONPower onPower on
    OFFPower offPower off
    Flash

    Program period indication,

    Only the blue led flashes the program routine can be done

    Program can be carried on


    Quality MF30 Series Ultrasonic Distance Sensor 200mm - 6000mm Detection Range with NPN PNP Anolog Output for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)