Sign In | Join Free | My burrillandco.com
Home > Electromagnetic Flow Meter >

Flow Velocity Electromagnetic Water Meter With High Performance GXEFM3000

    Buy cheap Flow Velocity Electromagnetic Water Meter With High Performance GXEFM3000 from wholesalers
     
    Buy cheap Flow Velocity Electromagnetic Water Meter With High Performance GXEFM3000 from wholesalers
    • Buy cheap Flow Velocity Electromagnetic Water Meter With High Performance GXEFM3000 from wholesalers
    • Buy cheap Flow Velocity Electromagnetic Water Meter With High Performance GXEFM3000 from wholesalers

    Flow Velocity Electromagnetic Water Meter With High Performance GXEFM3000

    Ask Lasest Price
    Brand Name : Kacise
    Model Number : GXEFM3000
    Certification : certificate of explosion-proof, CE
    Price : Negotiable
    Payment Terms : L/C, D/A, T/T, D/P, Western Union, MoneyGram
    Supply Ability : 1000 Pieces per Week
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    Flow Velocity Electromagnetic Water Meter With High Performance GXEFM3000

    Flow Velocity Electromagnetic Water Meter With High Performance GXEFM3000

    Description


    GXEFM3000 electromagnetic flow meters are intended for fluid measurement in most industries including water, wastewater, food and beverage, pharmaceutical and chemical.

    There are two basic components of electromagnetic flow meter: 1) The Detector,

    which includes the flow tube, isolating liner and measuring electrodes, and 2) The Converter, which is the electronic device responsible for signal processing, flow calculation, display and output signals.

    The materials of construction of the wetted parts( liner and electrodes) should be appropriate for the specification on the intended type of service. Revise of the compatibilities consistent with the shipment of each meter.


    Technical Data


    Measuring system


    Measuring principleFaraday’s law
    Application rangeElectrically conductive fluids
    Measured Value
    Primary measured valueFlow velocity
    Secondary measured valueVolume flow

    Design


    FeaturesFully welded maintenance-free sensor
    Flange version with full bore flow tube
    Standard as well as higher pressure ratings
    Large diameter range from DN15~3000 with rugged liners approved for drinking water
    Industry specific insertion lengths
    Modular constructionThe measurement system consists of a flow Sensor and a signal converter. It is available as compact and as separate version
    Compact versionWith 511B converter: 110~240Vac Power
    With 521B converter: 18~36V DC Power
    With W800L/W800W: Battery Power
    Remote version

    In wall mount version with 211B converter

    (110~240Vac or 221B converter 18~36V DC

    With W800F converter: Battery Power
    Measurement range-12…+12m/s /-40...+40ft/s

    Measuring accuracy


    Reference conditionsFlow conditions similar to EN 29104
    Medium: water
    Electrical conductivity: ≥300μs/cm
    Temperature: +10~+30℃/+50~+80℉

    Inlet setion: ≥5DN
    Operating pressure: 1Bar/14.5psig
    Flow Meter AccuracyStandard: 0.5% of rate
    Optional: 0.2% of rate

    Operating conditions


    Temperature
    Process temperatureHard rubber liner: -5~+60℃
    Polypropylene liner: -5~+90℃
    PTEF liner: -5~+120℃
    Ambient temperatureStandard (with aluminum converter housing)

    -20~+60℃ (Protect electrics against self-heating

    with ambient temperature above 55℃

    Stroage temperature-20~70℃
    Pressure
    EN 1092-1DN2200~3000: PN2.5
    DN1200~2000: PN6
    DN200~1000: PN10
    DN65~150: PN16
    DN10~50: PN40
    Other pressure on request
    ISO insertion lengthOptional for DN15~600
    ASME B16.51~24”: 150lb RF
    Other pressure on request
    JISDN10~1000/ 2~40”: 10K
    Other pressure on request
    Pressure dropNegligible

    Fluid
    Physical conditionConductive liquids
    Electrical conductivity≥5μs/cm
    Permissible gas content (volume)≤5%
    Permissible solid content≤70%

    Installation conditions


    InstallationTake care that flow sensor is always fully filled
    For detailed information see chapter “Cautions for installation”
    Flow directionForward and reverse
    Arrow on flow sensor indicates positive flow direction
    Inlet run≥5 DN
    Outlet run≥2 DN

    Process connection


    Flange
    EN1092-1DN25~3000 in PN6~40
    ASME1~120” in 150 lb RF
    JIS25~1000 in 10~20k
    Design of gasket surfaceRF
    Other sizes or pressure ratings on request

    Ordering information


    Model Suffix Code Description
    GXEFM3000-1200-Com-4mA-Hart-DC-Pt-Teflon1-GR-D1400-Exd IIC T6 Gb 
    Diameter-XXXX         Four Digitals: for example:0010: 10mm: 0015:15mm 0100: 100mm 1000: 1000mm
    Transmitter-Com        Compact type
    -Rem        Remote type
    -Bat        Battery power supply type
    -PRO        process control type
    Signal Outpt-N       No output
    -4mA       4-20mA
    -Pul       1~5KHz pulse
    -4Pul       4~20mA / 1~5KHz
    Communication-N      No communication
    -Hart      HART
    -MOD      MODBUS-RTU
    -PRO      PROFIBUS
    -GPRS      GPRS net
    -CDMA      CDMA net
    -WHRT      Wireless HART
    -Other      special order
    Power Supply-AC     85V~250Vac@46~63Hz
    nominal 20W
    -DC     20~36VDC nominal 20W
    -Bat     Battery power supply
    -Bat+     Battery +12Vdc dual power supply
    Other     special request
    Electorde Material-316L    Stainless steel 316L
    -HasB    Hastelloy B
    -HasC    Hastelloy C276
    -Pt    Platinum
    -Ta    Tantalum
    -Ti    Titanium
    -WC    wolfram carbide
    Liner material-Rub1   Neoprene(-20-60℃)
    -Rub2   Neoprene(-20-90℃)
    -Tef1   polytetrafluroethylene(-30-120℃)
    -Tef2   polytetrafluroethylene(-20-160℃)
    -P   Polyurethane
    -FVMQ   FVMQ
    -PFA   DFA
    -ETFE   Ethylene tetraflurorethylene
    Grounding Ring-N  No grounding ring
    -GR  Grounding ring
    -GE  Grounding Electrode
    Wet part Connection attribute-DXX DXX: D06, D10, D16, D25,D40 D06: DIN PN6:
    D10: DIN PIN10D16: DIN PN16; D25: DIN PN25 D40: DIN PN40 etc
    -AX AX: A1, A3, A6 A1: ANSI 150#; A3: ANSI 300# A6: ANSI 600#
    -JX JX: J1, J2, J3 J1: JIS10K;
    J2: JIS 20K; J3: JIS 30K
    -WF Wafer connection (available for DN2.5; DN6 flow meter) Body material: stainless steel
    -TR Tri-Clamp for sanitary type (Body material: stainless steel)
    Explosive-proof grade-Exd IIC T6 GbExd IIC T6 Gb
    -Ndon't need