Sign In | Join Free | My burrillandco.com
Home > Fluid Level Meter >

KLD803 4 - 20mA / HART / RS485 Modbus Radar Distance Sensor For Solid Powder Particle Block

    Buy cheap KLD803 4 - 20mA / HART / RS485 Modbus Radar Distance Sensor For Solid Powder Particle Block from wholesalers
     
    Buy cheap KLD803 4 - 20mA / HART / RS485 Modbus Radar Distance Sensor For Solid Powder Particle Block from wholesalers
    • Buy cheap KLD803 4 - 20mA / HART / RS485 Modbus Radar Distance Sensor For Solid Powder Particle Block from wholesalers
    • Buy cheap KLD803 4 - 20mA / HART / RS485 Modbus Radar Distance Sensor For Solid Powder Particle Block from wholesalers
    • Buy cheap KLD803 4 - 20mA / HART / RS485 Modbus Radar Distance Sensor For Solid Powder Particle Block from wholesalers
    • Buy cheap KLD803 4 - 20mA / HART / RS485 Modbus Radar Distance Sensor For Solid Powder Particle Block from wholesalers

    KLD803 4 - 20mA / HART / RS485 Modbus Radar Distance Sensor For Solid Powder Particle Block

    Ask Lasest Price
    Brand Name : KACISE
    Model Number : KLD803
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 1000 Piece/Pieces per Week negotiable
    Delivery Time : 5-8 work days
    Certification : CE
    • Product Details
    • Company Profile

    KLD803 4 - 20mA / HART / RS485 Modbus Radar Distance Sensor For Solid Powder Particle Block

    1. Product Overview

    Radar level sensor antenna emits and narrow microwave pulse. This pulse propagates in space at the speed of light. When it encounters the surface of the measured medium, part of its energy is reflected back and received by the same antenna. The time interval between the transmitted pulse and the received pulse is proportional to the distance from the antenna to the surface of the measured medium. The 80GHz intelligent series radar level gauge is suitable for non-contact continuous measurement of the level of liquid, slurry, granular material and block material. Applicable In the occasions where temperature and pressure change greatly, inert gas and volatilization exist.

    The hardware system uses advanced microprocessors and embedded system processing software. The signal algorithm processing integrates advanced Echo-capture signal processing technology. This makes the product applicable to various complex industrial plant conditions.
    The “empty tank pretreatment” technology enables the instrument to correctly identify effective echoes and obtain correct measurement results even in the presence of multiple false echo interference.
    Not affected by various complicated working conditions. Such as strong surface fluctuations, foam, moisture and dust interference.


    2.Product Introduction

    Model KLD803
    Application of solid powder, particle and block
    Measuring range 0-120m
    Process connecting flange
    Antenna size 78mm lens antenna (PTFE integral filled antenna)
    Accuracy ± 5mm
    Protection grade IP67
    Explosion proof grade Exd IIC T6 Gb
    Frequency 76-81GHz
    Power supply two wire/four wire/six wire system (DC24V/AC220V)
    Signal output 4~20mA/HART/RS485 Modbus
    Display/programming programmer with Bluetooth/5G remote network debugging


    3.Technical Specifications

    Transmission Frequency76GHz~81GHz
    Measuring Range0~120m (liquid)
    Measurement Accuracy±2mm
    Beam Angle3°/6°
    Range Of Dielectric Constant Used≥2
    Power Supply Range

    DC24V/AC220V

    2-wire system/4-wire system/6-wire system

    Communication Mode

    MODBUS bus

    HART

    Signal Output

    4~20mA+RS485

    4~20mA

    Fault Output3.8mA, 4mA, 20mA, 21mA, hold
    Field Operation/Programming

    128 × 64 dot matrix display/4 buttons

    can be equipped with host setting software

    Industrial Temperature/Humidity

    T0:-40~85℃/≤95%RH;T1:-40~200℃;

    T2:-40~500℃; T3:-40~1000℃

    Shell MaterialCast aluminum, stainless steel
    Antenna TypeLens antenna
    Process Pressure-0.1~2.5MPa
    Cable EntryM20 * 1.5 or 1/2NPT
    Recommended cableAWG18 or 0.75mm ²
    Degree of protectionIP67
    Explosion proof gradeExd IIC T6 Gb
    Installation methodThread or flange
    Net weight/gross weightRandom configuration
    Packing box sizeRandom configuration
    Transmission frequency76GHz~81GHz

    4.Structural dimensions

    Schematic Diagram of Pipe Thread Process Connection Structure Size at Room Temperature

    5. Installation
    Two points for installation:
    (1) Align the target material level to ensure that it is perpendicular to the material level plane;
    (2) Avoid false echoes. See the following points for typical working conditions.
    ● Ensure that there are no interfering objects, such as ladders and steps, within the beam range.

    Figure 5 – 1 Schematic Diagram of Instrument Installation Position

    ● The instrument installation shall ensure that the antenna beam avoids the feed inlet, as shown in Figure 5-2.

    Figure 5 – 2 Antenna beam avoiding feed inlet

    ● The instrument shall be installed at least 20cm away from the vessel wall, otherwise it is likely to produce wrong readings, as shown in Figure 5-3.
    Remarks: The liquid measurement installation spool should be perpendicular to the ground.

    Figure 5 – 3 Installation at least 20cm away from the vessel wall

    ● The solid cone container shall ensure that the beam is directed at the tank bottom as much as possible, otherwise the measurement results at the tank bottom may be inaccurate, as shown in Figure 5-4.

    Figure 5 – 4 The conical tank shall ensure that the beam is directed at the tank bottom as far as possible.

    6. Product wiring diagram
    6.1 Wiring diagram of single chamber enclosure 24VDC power supply four wire products

    Fig. 6-1 Wiring Diagram of Four wire Products
    In four wire system application, 4-20mA analog output is two separate terminals except 24V power supply terminal. At the same time, the four wire system also provides 485 output terminals, which is convenient for connection and debugging with PC or the site requiring 485 interface.

    6.2 Wiring diagram of single chamber enclosure 24VDC power supply two-wire product

    Fig.6-1 Wiring diagram of two-wire products

    In the two-wire system application, in addition to the traditional power supply terminal (4-20mA output), the instrument also has a serial communication terminal, which is convenient to connect with the current mainstream IOT equipment or transparent transmission equipment for remote control and debugging.


    Model Selection Table
    80GHz FM radar level meter

    ModelModel KLD801
    Licence

    P Standard type (non explosion proof)

    I Intrinsically safe(Exia IIC T6 Ga)

    D Flameproof type(Exd IIC T6 Gb)

    Process connection

    B Flange DN80/304

    C Flange DN100/304

    D Flange DN125/304

    E Flange DN150/304

    Y Special customization

    Antenna type/material

    P 78mm Lens antenna

    Y Special customization

    Process temperature

    V Standard/(-40~120℃)

    Y Special customization

    Electronic unit

    2 (4-20)mA/24V DC Two wire

    3 (4-20)mA/24V DC/HART Two wire

    4 (4-20)mA/220V DC Four wire

    5 RS485/Modbus/24V DC Four wire

    6 (4-20)mA/RS485 /24V DC Six wire dual output

    Enclosure/degree of protection

    L Aluminium/IP67 Single cavity

    B Aluminium/IP67 Double cavity

    J stainless steel 304/IP68 Single cavity

    Cable incoming line

    M M20*1.5

    N ½NPT

    Quality KLD803 4 - 20mA / HART / RS485 Modbus Radar Distance Sensor For Solid Powder Particle Block for sale