Sign In | Join Free | My burrillandco.com
Home > Fluid Level Meter >

Channel River Radar Water Level Sensor Support Remote Debug KLD801

    Buy cheap Channel River Radar Water Level Sensor Support Remote Debug KLD801 from wholesalers
     
    Buy cheap Channel River Radar Water Level Sensor Support Remote Debug KLD801 from wholesalers
    • Buy cheap Channel River Radar Water Level Sensor Support Remote Debug KLD801 from wholesalers
    • Buy cheap Channel River Radar Water Level Sensor Support Remote Debug KLD801 from wholesalers
    • Buy cheap Channel River Radar Water Level Sensor Support Remote Debug KLD801 from wholesalers
    • Buy cheap Channel River Radar Water Level Sensor Support Remote Debug KLD801 from wholesalers
    • Buy cheap Channel River Radar Water Level Sensor Support Remote Debug KLD801 from wholesalers
    • Buy cheap Channel River Radar Water Level Sensor Support Remote Debug KLD801 from wholesalers

    Channel River Radar Water Level Sensor Support Remote Debug KLD801

    Ask Lasest Price
    Brand Name : KACISE
    Model Number : KLD801
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 1000 Piece/Pieces per Week negotiable
    Delivery Time : 5-8 work days
    Certification : CE
    • Product Details
    • Company Profile

    Channel River Radar Water Level Sensor Support Remote Debug KLD801

    1. Product Overview
    KLD80 series products are frequency modulated continuous wave (FMCW) radar products operating at 76-81GHz, supporting four-wire and two-wire applications. There are multiple models, the maximum range of the product can reach 120m, and the blind area can reach 8cm. Because of its higher operating frequency and shorter wavelength, it is especially suitable for solid-state applications. The working method of transmitting and receiving electromagnetic waves through a lens has unique advantages in high dust and harsh temperature environments (+200°C). The instrument provides flange or threaded fixing, which makes the installation convenient and easy.

    The main advantages of KLD80 series FM radar level meter are as follows:

    • Based on the self-developed CMOS millimeter-wave radio frequency chip, it realizes a more compact radio frequency structure, a higher signal-to-noise ratio, and a smaller dead zone.
    • The 5GHz operating bandwidth enables the product to have higher measurement resolution and measurement accuracy.
    • The narrowest 3° antenna beam angle, the interference in the installation environment has less impact on the instrument, and the installation is more convenient.
    • Shorter wavelengths and better reflection properties on solid surfaces.
    • Support remote debugging and remote upgrade, reduce waiting time and improve work efficiency.
    • Support mobile phone Bluetooth debugging, convenient for on-site personnel maintenance work.

    Communication and debugging
    The instrument can be debugged through LDM in the field, and can also be debugged on the PC side with the optional host computer software. The connection between the meter and the PC is as follows:
    to communicate with:
    1. USB to RS485 serial cable (four-wire system);
    2. USB to TTL serial cable (two-wire system);
    3. USB to Hart-modem (two-wire system) for communication.
    4. Through the mobile phone Bluetooth debugging, the on-site debugging is safer and more convenient.
    5. 4G network, remote debugging through remote module.

    2.Product Introduction

    Model KLD801

    Application liquid, weak corrosive liquid

    Measuring range 0-10m

    Process connection thread/flange

    Antenna size 22mm lens antenna

    Accuracy ± 2mm

    Protection grade IP67

    Explosion proof grade Exd IIC T6 Gb

    Frequency 76-81GHz

    Power supply two wire/four wire/six wire system (DC24V/AC220V)

    Signal output 4~20mA/HART/RS485 Modbus

    Display/programming programmer with Bluetooth/5G remote network debugging


    3.Technical Specifications

    Transmission Frequency76GHz~81GHz
    Measuring Range0~120m (liquid)
    Measurement Accuracy±2mm
    Beam Angle3°/6°
    Range Of Dielectric Constant Used≥2
    Power Supply Range

    DC24V/AC220V

    2-wire system/4-wire system/6-wire system

    Communication Mode

    MODBUS bus

    HART

    Signal Output

    4~20mA+RS485

    4~20mA

    Fault Output3.8mA, 4mA, 20mA, 21mA, hold
    Field Operation/Programming

    128 × 64 dot matrix display/4 buttons

    can be equipped with host setting software

    Industrial Temperature/Humidity

    T0:-40~85℃/≤95%RH;T1:-40~200℃;

    T2:-40~500℃; T3:-40~1000℃

    Shell MaterialCast aluminum, stainless steel
    Antenna TypeLens antenna
    Process Pressure-0.1~2.5MPa
    Cable EntryM20 * 1.5 or 1/2NPT
    Recommended cableAWG18 or 0.75mm ²
    Degree of protectionIP67
    Explosion proof gradeExd IIC T6 Gb
    Installation methodThread or flange
    Net weight/gross weightRandom configuration
    Packing box sizeRandom configuration
    Transmission frequency76GHz~81GHz

    4.Structural dimensions

    Schematic Diagram of Pipe Thread Process Connection Structure Size at Room Temperature

    5. Installation
    Two points for installation:
    (1) Align the target material level to ensure that it is perpendicular to the material level plane;
    (2) Avoid false echoes. See the following points for typical working conditions.
    ● Ensure that there are no interfering objects, such as ladders and steps, within the beam range.

    Figure 5 – 1 Schematic Diagram of Instrument Installation Position

    ● The instrument installation shall ensure that the antenna beam avoids the feed inlet, as shown in Figure 5-2.

    Figure 5 – 2 Antenna beam avoiding feed inlet

    ● The instrument shall be installed at least 20cm away from the vessel wall, otherwise it is likely to produce wrong readings, as shown in Figure 5-3.
    Remarks: The liquid measurement installation spool should be perpendicular to the ground.

    Figure 5 – 3 Installation at least 20cm away from the vessel wall

    ● The solid cone container shall ensure that the beam is directed at the tank bottom as much as possible, otherwise the measurement results at the tank bottom may be inaccurate, as shown in Figure 5-4.

    Figure 5 – 4 The conical tank shall ensure that the beam is directed at the tank bottom as far as possible.

    6. Product wiring diagram
    6.1 Wiring diagram of single chamber enclosure 24VDC power supply four wire products

    Fig. 6-1 Wiring Diagram of Four wire Products
    In four wire system application, 4-20mA analog output is two separate terminals except 24V power supply terminal. At the same time, the four wire system also provides 485 output terminals, which is convenient for connection and debugging with PC or the site requiring 485 interface.

    6.2 Wiring diagram of single chamber enclosure 24VDC power supply two-wire product

    Fig.6-1 Wiring diagram of two-wire products

    In the two-wire system application, in addition to the traditional power supply terminal (4-20mA output), the instrument also has a serial communication terminal, which is convenient to connect with the current mainstream IOT equipment or transparent transmission equipment for remote control and debugging.


    Model Selection Table
    80GHz FM radar level meter

    ModelModel KLD801
    Licence

    P Standard type (non explosion proof)

    I Intrinsically safe(Exia IIC T6 Ga)

    D Flameproof type(Exd IIC T6 Gb)

    Process connection

    G 1 ½threads

    A Flange DN50/304

    B Flange DN80/304

    C Flange DN100/304

    D Flange DN125/304

    E Flange DN150/304

    Y Special customization

    Antenna type/material

    P 22mm Lens antenna

    Y Special customization

    Process temperature

    V Standard/(-40~120℃)

    Y Special customization

    Electronic unit

    2 (4-20)mA/24V DC Two wire

    3 (4-20)mA/24V DC/HART Two wire

    4 (4-20)mA/220V DC Four wire

    5 RS485/Modbus/24V DC Four wire

    6 (4-20)mA/RS485 /24V DC Six wire dual output

    Enclosure/degree of protection

    L Aluminium/IP67 Single cavity

    B Aluminium/IP67 Double cavity

    J stainless steel 304/IP68 Single cavity

    Cable incoming line

    M M20*1.5

    N ½NPT

    Quality Channel River Radar Water Level Sensor Support Remote Debug KLD801 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)