Sign In | Join Free | My burrillandco.com
Home > Gas Detector Sensor >

1000ppm Infrared SF6 Gas Sensor High Resolution,T90 Pipeline Type of Pump suction 50s

    Buy cheap 1000ppm Infrared SF6 Gas Sensor High Resolution,T90 Pipeline Type of Pump suction 50s from wholesalers
     
    Buy cheap 1000ppm Infrared SF6 Gas Sensor High Resolution,T90 Pipeline Type of Pump suction 50s from wholesalers
    • Buy cheap 1000ppm Infrared SF6 Gas Sensor High Resolution,T90 Pipeline Type of Pump suction 50s from wholesalers
    • Buy cheap 1000ppm Infrared SF6 Gas Sensor High Resolution,T90 Pipeline Type of Pump suction 50s from wholesalers

    1000ppm Infrared SF6 Gas Sensor High Resolution,T90 Pipeline Type of Pump suction 50s

    Ask Lasest Price
    Brand Name : Kacise
    Model Number : KSS572
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 1000 Pieces per Week
    Delivery Time : 5 work days
    Certification : certificate of explosion-proof, CE
    • Product Details
    • Company Profile

    1000ppm Infrared SF6 Gas Sensor High Resolution,T90 Pipeline Type of Pump suction 50s


    KSS572 Infrared SF6 Sensor

    1. overview

    SF6 gas is widely used as an insulating medium and arc extinguishing gas in power equipment, especially in high-voltage circuit breakers, transformers, transformers, capacitors, arresters, fuses, etc. Leakage occurs, equipment pressure decreases, insulation capacity is reduced; Pollute and destroy the atmospheric environment, increase the greenhouse effect; Accumulation in low-level spaces, resulting in accidents such as lack of oxygen in the brains of staff and even rapid asphyxiation; Under the influence of partial discharge, high temperature and other factors, SF6 gas will produce highly toxic decomposition substances such as SF4, SF2, SOF2, etc.

    KSS572 is a gas sensor module using NDIR infrared absorption detection principle. The concentration is determined according to the absorption of SF6 gas at 10.5um. The single-light source and dual-channel structure of MEMS light source, dual-channel pyroelectric detector and optical gas chamber are used to realize the reference compensation of the spatial dual optical path. Microprocessors perform signal acquisition, processing, and output, with temperature compensation and nonlinearity correction.

    2. Technical parameters

    parametersymbolminimumTypical valuesmaximumunit
    Storage TemperatureTstg-20-80°C
    Operating TemperatureTA-2060°C
    Operating HumidityHA090% RH
    Work PressurePA0.81.2atm
    Supply VoltageVs111230V
    Maximum Operating CurrentIavg100120150mA
    Detection Range (customizable).Ra1000ppm
    ResolutionResolution1000ppm
    Measurement AccuracyAcurracy± 10ppm or ±5% truth value%vol
    T90 Pipeline TypePump suction5second
    Diffusion30second
    RepeatabilityZeroLess than ±50ppm
    RangeLess than ±5%.
    Life Span10year

    3. Structural dimension drawing

    Unit: mm

    Pump suction structure dimensional drawing



    Dimensional drawing of diffused structure


    4. Installation instructions

    The sensor is installed and positioned at a distance of 3.2mm according to the structural requirements

    The wiring socket pitch is 2.54 mm.

    5. Matters that should be paid attention to in maintenance

    The sensor should be calibrated regularly, it is recommended that it be no more than 3 months, and calibration is not required on the long-term operation side if automatic calibration is turned on do not use the sensor for a long time in an environment with a high density of dust.

    Please use the sensor within the range of the sensor's power supply.

    6. Ordering Instructions

    In order to be able to purchase the specific specifications required, please provide the following information

    1) Sensor name 2) Sensor range 3) Sensor measurement accuracy and output mode, etc

    For example, SW521, 0-5000ppm, 4-20mA output


    7. Order Information


    Order information sheet
    KSS572KSS572 CO2 concentration sensor
    xxxxThe sensor measures the range of CO2 concentration in ppm, with a minimum value of 2000 and a maximum value of 50000 ppm.
    2000Range 200ppm (default).
    10000Range 10000ppm
    50000Range 50000ppm
    encodeThe reaction speed is divided into two types: fast and slow
    SSlow (default).
    Qfast
    encodeBaud rate selection, support commonly used baud rate 2400 9600 19200 38400bps, 8 bits of data, 1 bit of stop bit, no check bit: Confirm special needs before ordering.
    CustomConfirm the baud rate before ordering
    24002400bps baud rate
    96009600bps baud rate
    1920019200bps baud rate
    3840038400bps baud rate (default)
    encodeSerial port protocol
    Modbus-RTUStandard Modbus-RTU protocol (default).
    Modbus-ASCIIStandard Modbus-ASCII protocol
    Modbus-SelfModbus private protocol
    KSS572-2000-S-38400-Modbus-RTU

    9. Contact Details

    URL: www.kacise.com

    Tel: +86-29-17719566736

    Email: sales@kacise.com

    Address: Tangyan South Road, Xi'an City, Shaanxi Province, China


    10.Appendix


    ShorthandFull name
    VOL1% VOL refers to 1% of the volume of a particular gas in air.
    PPM1PPM means that the volume of a specific gas in the air accounts for one millionth.
    O2Oxygen molecules
    LCDLCD display
    RS485Asynchronous serial port 485
    DCdirect current
    ACCommunication
    PVCpolyvinyl chloride

    Quality 1000ppm Infrared SF6 Gas Sensor High Resolution,T90 Pipeline Type of Pump suction 50s for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)