Sign In | Join Free | My burrillandco.com
Home > Ultrasonic Transducer Sensor >

Ultrasonic Sensor for Distance and Level Measurement of KUS630

    Buy cheap Ultrasonic Sensor for Distance and Level Measurement of KUS630 from wholesalers
     
    Buy cheap Ultrasonic Sensor for Distance and Level Measurement of KUS630 from wholesalers
    • Buy cheap Ultrasonic Sensor for Distance and Level Measurement of KUS630 from wholesalers
    • Buy cheap Ultrasonic Sensor for Distance and Level Measurement of KUS630 from wholesalers
    • Buy cheap Ultrasonic Sensor for Distance and Level Measurement of KUS630 from wholesalers
    • Buy cheap Ultrasonic Sensor for Distance and Level Measurement of KUS630 from wholesalers
    • Buy cheap Ultrasonic Sensor for Distance and Level Measurement of KUS630 from wholesalers
    • Buy cheap Ultrasonic Sensor for Distance and Level Measurement of KUS630 from wholesalers

    Ultrasonic Sensor for Distance and Level Measurement of KUS630

    Ask Lasest Price
    Brand Name : kacise
    Model Number : KUS630
    Certification : ce
    Price : 850 RMB
    Payment Terms : D/A, D/P, T/T, Western Union, MoneyGram, L/C
    Supply Ability : 100+
    • Product Details
    • Company Profile

    Ultrasonic Sensor for Distance and Level Measurement of KUS630


    KUS630 Series Ultrasonic Level Meter


    1.Features

    • High sensitivity.
    • Fully sealed
    • IP68 protection class
    • Corrosion-resistant housing, suitable for corrosive media and applications

    2. Dimensions

    Unit in the diagram is mm.

    3. Electrical connections and signal definitions

    Line orderColourDefinition
    1RedPower is positive
    2Blackpower return ground
    3YellowAnalog output, voltage output, current output switch output
    4BlueRS485 A+ or uart TXD
    5GreenRS485 B- or uart RXD

    Cable colorLine orderDescribeRemark
    red1powered by3.3V-30V wide voltage input
    black2GND
    yellow3Switch outputSwitch terminal, load capacity 1A 60V, supports up to two switch outputs with independent logic, the two terminals are the two contacts of the switch, do not distinguish between positive and negative poles, and can be connected at will.
    White4Switch output
    brown4RS485A+
    green5RS485B-


    4.Parameter description



    Working current

    ≤ 45 mA (fastest measurement speed)

    Low-power version, sleep power consumption is less than 0.3mA, sending power consumption is 20mA (less than 2ms), and receiving power consumption is not more than 8mA (less than 150ms)


    Output signal

    1:Programmable analog output 0-10V.

    2:RS485 output.

    3:Uart serial output

    4:4-20mA output

    5:Switch output

    Measurement accuracy≤1 %
    Temperature compensationyes

    working conditions


    Working temperature-25…70℃(248...343K)
    Storage temperature-40…85℃(233...358K)

    other instructions


    Electrical connection5-core cable (analog output), 6-core cable (switch output);
    Protection classIP68
    Shell materialPVC /PVDF/PTFE/ABS

    5. Sensor function

    analog

    The analog output can be set through RS485, and the sensor can work in 8 modes. The specific reference is as follows:

    Step 1: Connect to the host computer through serial port debugging assistant or modus debugging assistant.

    Step 2, set a near point reference distance point.

    Step 3, Set a far point reference point

    Step 4, set the output voltage or current of the near-point reference point.

    Step 5, set the output voltage or current of the far point reference point.

    Step 6, set the analog output to switch characteristic selection.

    Step 7, set the analog output as linear output or switch output option.

    Step 8, reset the sensor to make the new parameters take effect.

    8 working modes of the sensor.

    1: Open window mode by default

    2: Windowed mode is turned off by default

    3: Single-point mode is turned on by default

    4: Single-point mode is turned off by default

    5: Single-point hysteresis mode is turned on by default

    6: The single-point hysteresis mode is turned off by default

    7: The presence or absence of detection mode is turned on by default

    8: The presence or absence of detection mode is turned off by default


    485 output data

    485 output data is in MODBUS-RTU format. Refer to the software instruction manual for details.


    6.Serial port setting output form example


    7. Ordering Information



    KUSModelOutputRangeDescribe
    630AProduct series model and shape, the default delivery is TypeA, support customization
    630B
    630C
    Custommade
    0-10VAnalog 0-10V output
    0-5VAnalog 0-5V output
    0-3VAnalog 0-3V output
    4-20mAAnalog 4-20mA output
    SWSwitch output
    UartUart serial output MODBUS RTU protocol
    RS485RS485 output MODBUS RTU protocol
    XXX mm

    XXX mmmeans the maximum measurement distance

    (default1000mm)

    KUS550RS48510000mm