Sign In | Join Free | My burrillandco.com
Home > Ultrasonic Transducer Sensor >

Ultrasonic Sensor for Distance and Level Measurement of KUS550

    Buy cheap Ultrasonic Sensor for Distance and Level Measurement of KUS550 from wholesalers
     
    Buy cheap Ultrasonic Sensor for Distance and Level Measurement of KUS550 from wholesalers
    • Buy cheap Ultrasonic Sensor for Distance and Level Measurement of KUS550 from wholesalers
    • Buy cheap Ultrasonic Sensor for Distance and Level Measurement of KUS550 from wholesalers
    • Buy cheap Ultrasonic Sensor for Distance and Level Measurement of KUS550 from wholesalers
    • Buy cheap Ultrasonic Sensor for Distance and Level Measurement of KUS550 from wholesalers
    • Buy cheap Ultrasonic Sensor for Distance and Level Measurement of KUS550 from wholesalers
    • Buy cheap Ultrasonic Sensor for Distance and Level Measurement of KUS550 from wholesalers
    • Buy cheap Ultrasonic Sensor for Distance and Level Measurement of KUS550 from wholesalers

    Ultrasonic Sensor for Distance and Level Measurement of KUS550

    Ask Lasest Price
    Brand Name : kacise
    Model Number : KUS550
    Certification : ce
    Price : 550 RMB/piece
    Payment Terms : D/A, D/P, T/T, Western Union, MoneyGram, MoneyGram
    Supply Ability : 1000
    • Product Details
    • Company Profile

    Ultrasonic Sensor for Distance and Level Measurement of KUS550

    KUS550 Series Ultrasonic Sensor


    1. Features

    • High sensitivity.
    • Compact and robust structure.
    • IP68 high protection rating.
    • Corrosion resistant casing, suitable for corrosive medium and application

    2. Dimension

    Unit in the diagram is mm.

    3. Electronic interface and signals definition

    Analogue output type wiring diagram



    Switch output type wiring diagram

    4. Parameter

    General specifications


    Model: KUS550
    Measuring range

    0.25m~3m (5m customizable)KUS550A

    0.15m-0.6m(1m customizable)KUS550B;

    Blind spotThe dead zone of KUS550A is 0 ... 250 mm (within 250mm is unstable working zone, it is not recommended to work in this range); the dead zone of KUS550B is 0-150mm;
    Supply voltage3.3 ... 30 VDC, ripple 10 %SS
    Working current≤ 45 mA (fastest measurement speed), typical power consumption ≤ 10 mA;

    Output signal

    0-10V. 0-3V 0-5V /4-20mA/NPN/PNP/RS485 Analog output.
    Measurement accuracy≤1 %F.S.
    Temperature compensationYes
    Ranging resolution0.1mm;

    Working conditions

    Working temperature-40…85℃(233...358K)
    Storage temperature-40…85℃(233...358K)

    Other instructions

    Electrical connection5-core cable (analog output), 6-core cable (switch output);
    Protection classIP67
    shell materialPVC /PVDF/PTFE/ABS

    5. Description of Sensor Functions

    Adjusting the analogue output.

    The analogue output can be programed as the user want. Such as working at switch output or working at liner output all the parameters can be set by the RS485 interface.

    There is 8 types of output functions can be programed.

    All the setting routine as follows,

    step 1 set one pointed distance by the RS485,

    step 2 set another pointed distance by the RS485.

    Step3 set the output type liner or switch, and set the related output options

    Step4 reboot the sensor.

    1. Window mode normally-open and liner mode positive slope output function.

    2. Window mode normally-closed and liner mode negative slope output function.

    3. Single switching point, normally-open function.

    4. Single switching point, normally-closed function.

    5. Single switch point with hysteresis gap normally-open function.

    6. Single switch point with hysteresis gap normally-closed function.

    7. Detection of object presence-normal open function.

    8. Detection of object presence-closed open function.

    Switching point, Setting distance only after power on. The internal clock can assure can't be changed after 5 minutes after power on. If want to change the switching point, the user can only setting the request distance after power restart.

    For the RS485 output type.

    There are 2 kinds of working style,

    One for auto measure, the sensor will measure the distance or level repeatedly, and the measurement period can be set by the UART. The measure result can be fetched every time.

    The other style is power save mode when the sensor is sleep, until the sensor received the inquiry command with pre-code. Communication protocol is Modus-RTU.

    For example the measure result can be read by access the register 0x101 by Modbus protocol.

    For more information please contact us for the software engineering guide.


    6. Window mode normally-open and liner mode positive slope output function program routine diagram.


    7. Installation conditions

    If the sensor is installed at the environment temperature fall below 0℃, It should do well on the protective measures. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread.


    8. Ordering information

    KUSModelOutputMax rangeDescription
    550
    Customized
    SWSwitch Output
    mA3 wire 4-20mA output
    10VOutput is Vout 0-10V
    5VOutput is Vout 0-5V
    3VOutput is Vout 0-3V
    RS485Output is RS485
    TTLUART TTL output
    XX m

    XX m is the maxim range can be detected

    Default is 2.5m

    KUS550RS4852m