KUS650 ultrasonic tank level sensor
Application field
KUS650 series is used to indicate and monitor the changes of water
pressure/water level value at the installation site, and upload the
real-time data to the centralized management platform through the
built-in wireless transmission module, which is convenient for
users to manage intelligently and centralizedly. It is mainly used
in the following industries:
• Fire water system
• City water supply
• Sewage treatment
• Long-distance heating
• Food industry
• Chemical, energy
parameter settings
1 Sending time setting
Operation code: 2121 units (minutes)
In the measurement state, press the "M" key to display "-COd-";
press the "M" key to confirm, display "00000", the ones digit
flashes, press the "up and down" keys to adjust to "2121"; press
the "M" key to confirm, Display "S_TIM", press "M" key, display
"00000" (last setting value), and set the value (range 1) by "up"
key (data left key) and "down" key (data increase key) ~09999),
press "M" key to confirm and save after adjustment is completed.
2 Collection time interval setting
Operation code: 2122 units (seconds)
In the measurement state, press the "M" key to display "-COd-";
press the "M" key to confirm, display "00000", the ones digit
flashes, press the "up and down" keys to adjust to "2122"; press
the "M" key to confirm, Display "S_FrE", press "M" key, display
"00000" (last setting value), set the value (range 1~09999) with
"up" and "down" keys, press "M" after adjustment is completed Press
to confirm and save. On time interval setting.
3 Data upload method setting
Operation code: 2124
In the measurement state, press the "M" key to display "-COd-";
press the "M" key to confirm, display "00000", the ones digit
flashes, press the "up and down" keys to adjust to "2124"; press
the "M" key to confirm, Display "S.MOdE", press "M" key, display
"Last set value", set by "Up" and "Down" keys, press "M" key to
confirm and save after adjustment is completed.
4 Alarm interval time setting
Operation code: 2125 units (minutes)
In the measurement state, press the "M" key to display "-COd-";
press the "M" key to confirm, display "00000", the ones digit
flashes, press the "up and down" keys to adjust to "2125"; press
the "M" key to confirm, Display "S_ErT", press "M" key, display
"00000" (last setting value), set the value (range 1~09999) by "up"
and "down" keys, press "M" after adjustment is completed Press to
confirm and save.
5 Liquid level/material level alarm upper limit setting
Operation code: 2311
In the measurement state, press the "M" key to display "-COd-";
press the "M" key to confirm, display "00000", the ones digit
flashes, press the "up and down" keys to adjust to "2311"; press
the "M" key to confirm, Display "Ad1H", press the "M" key to set
the upper limit alarm value, set the value through the "up" and
"down" keys, the "Ad1F" alarm upper limit return difference, the
"Ad1d" alarm upper limit delay, all adjustments After completion,
press the "M" key to confirm and save.
6 Liquid level/level alarm lower limit setting
Operation code: 2312
In the measurement state, press the "M" key to display "-COd-";
press the "M" key to confirm, display "00000", the ones digit
flashes, press the "up and down" keys to adjust to "2312"; press
the "M" key to confirm, Display "Ad2H", press the "M" key to set
the upper limit alarm value, set the value through the "up" and
"down" keys, the "Ad2F" alarm upper limit return difference, the
"Ad2d" alarm upper limit delay, all adjustments After completion,
press the "M" key to confirm and save.
7 Instrument zero
Operation code: 1000
In the measurement state, press the "M" key to display "-COd-";
press the "M" key to confirm, display "00000", the ones digit
flashes, press the "up and down" keys to adjust to "1000"; press
the "M" key to confirm, Display "bd_0" and press the "up and down"
keys to select "NO (exit without calibration) or YES (calibrate
zero)". Press the "M" key to confirm saving and exit.
8 Meter zero cut
Operation code: 1511
In the measurement state, press the "M" key to display "-COd-";
press the "M" key to confirm, display "00000", the ones digit
flashes, press the "up and down" keys to adjust to "1511"; press
the "M" key to confirm, Display "CUTO", press "M" key, display
"00000" (last setting value), set the value (range 1~29999) by "up"
and "down" keys, press "M" after adjustment is completed Press to
confirm and save.
9 Meter offset setting
Operation code: 1510
In the measurement state, press the "M" key to display "-COd-";
press the "M" key to confirm, display "00000", the ones digit
flashes, press the "up and down" keys to adjust to "1510"; press
the "M" key to confirm, Display "OFSET", press "M" key, display
"00000" (the last set value), set the value (range -19999~29999)
with "up" and "down" keys, press "M" after adjustment "Key to
confirm and save.
parameters
Enter | |
Measured variable Liquid | level, material level |
Maximum measuremen trange | 1.2-30m (can be customized according to demand) |
Output | |
Comprehensive accuracy | ±0.15%FS/ 0.15℃ |
Temperature compensation | -10℃~70℃ |
Vibration effects | < ± 0.05%/g, 500Hz in all directions (according to IEC 68-2-64) |
way of communication
1 MODBUS communication
There are two types of MODBUS protocol: MODBUS-RTU (commonly used
in China)
MODBUS-ASCII
The communication protocol of this instrument complies with the
MODBUS-RTU communication protocol
Assuming that the instrument parameters are: The address of the
instrument is set to 1; the communication baud rate is 9600; the
invalid check digit; the decimal point is 0; the unit is KPa;
2 Wireless communication(NB-IoT/4G/LoRa)
According to different user needs, wireless communication has
different transmission methods and protocol contents. Please
consult for specific content.
Installation and maintenance
1 Installation
1) The meter should be installed on a vertical horizontal plane.
2) Pay attention to the range matching when using with other
instruments.
3) Before installing the digital meter on the equipment, first
check whether the meter head is clean. During use, the pipeline
should be kept clean.
2 Maintenance
1) The instrument is a high-precision instrument and should be
placed in a place with air circulation, easy to observe, easy to
maintain and operate.
2) Although the digital sensor can exceed the range during use,
long-term use will affect the accuracy of the measurement and may
damage the meter. It is recommended that the user use the meter
according to the range.
3) When the LCD screen of the wireless digital meter displays the
battery voltage as blank, please replace the battery to ensure the
normal operation of the measurement.
Note: The rechargeable battery can be charged, and the charging
time is 3~4 hours.
Company information
Xi'an Kacise Optronics Co., Ltd. was founded in 2000, is located in
Xi'an, Shaanxi Province, China, is a professional engaged in
instrumentation and sensors, R & D, production, sales as one of
professional high-tech enterprises, we have our own production
workshop and central laboratory. Factory building area is about
3000 square meters, with production of more than 30 employees, 8
engineer, 6 inspectors, 10 saleman, 5 for customer service, is this
industry, we are one of the strong technology manufacturers with
varieties specification.
When the company set up, we began to focus on the coordination of
military supplies production, achieved GB/T19001-2008/ISQ9001:2008,
GJB 9001B-2009 certification. When our company is running mature
and stable, in 2008, we began to develop our business. Based on the
production of military products quality control, we developed a lot
of sensor products, such as a pressure sensor / transducer /
sensor, level transmitter / ultrasonic level meter / ultrasonic
flow meter, inertial navigation products, IMU, gyroscope,
accelerometer etc.
![]() |