Sign In | Join Free | My burrillandco.com
Home > Fluid Level Meter >

3m Range 4 - 20mA Fluid Level Meter Small Diameter Ultrasonic Sensor For Industrial Automation

    Buy cheap 3m Range 4 - 20mA Fluid Level Meter Small Diameter Ultrasonic Sensor For Industrial Automation from wholesalers
     
    Buy cheap 3m Range 4 - 20mA Fluid Level Meter Small Diameter Ultrasonic Sensor For Industrial Automation from wholesalers
    • Buy cheap 3m Range 4 - 20mA Fluid Level Meter Small Diameter Ultrasonic Sensor For Industrial Automation from wholesalers
    • Buy cheap 3m Range 4 - 20mA Fluid Level Meter Small Diameter Ultrasonic Sensor For Industrial Automation from wholesalers
    • Buy cheap 3m Range 4 - 20mA Fluid Level Meter Small Diameter Ultrasonic Sensor For Industrial Automation from wholesalers

    3m Range 4 - 20mA Fluid Level Meter Small Diameter Ultrasonic Sensor For Industrial Automation

    Ask Lasest Price
    Brand Name : KACISE
    Model Number : KUS3000-M30
    Certification : CE
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union, MoneyGram
    Supply Ability : 1000 Piece/Pieces per Week negotiable
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    3m Range 4 - 20mA Fluid Level Meter Small Diameter Ultrasonic Sensor For Industrial Automation

    3m Range 4-20mA / 0-10V Small Diameter Ultrasonic Sensor For Industrial Automation


    Features


    Non-contact
    Teachable

    Measuring window adjustable

    Small unusable area


    Introduction


    Ultrasonic sensor measure is a reliability and outstanding versatility measurement method. It can realize to solve the most complex projects including object detection or level measure, because its measuring way works reliably under almost all conditions.


    Appliactions


    Level measuring

    Mechanical engineering
    Material handling

    Food industry
    Woodworking and furniture
    Agriculture
    Construction
    Paper making


    Dimensions


    Parameters


    General specifications


    M18
    Sensing range100... 1000 mm
    Adjustment range100….1000mm
    Unusable area0 ... 100 mm
    Standard target plate100 mm x 100 mm
    Transducer frequencyapprox.220 kHz
    Response delayapprox. 10 ms

    M30-type1
    Sensing range200... 2000 mm
    Adjustment range200….2000mm
    Unusable area0 ... 200 mm
    Standard target plate100 mm x 100 mm
    Transducer frequencyapprox.150 kHz
    Response delayapprox. 10 ms

    M30-type2
    Sensing range300... 3500 mm
    Adjustment range300….3500mm
    Unusable area0 ... 150 mm
    Standard target plate100 mm x 100 mm
    Transducer frequencyapprox.70 kHz
    Response delayapprox. 20 ms

    M30-type3
    Sensing range400... 6500 mm
    Adjustment range400….6500mm
    Unusable area0 ... 300 mm
    Standard target plate100 mm x 100 mm
    Transducer frequencyapprox.50 kHz
    Response delayapprox. 40 ms

    Indicators/operating means

    LED bluePower on
    LED yellowsolid: object in the evaluation range
    flashing: program function, object detected
    LED redsolid: Error
    flashing: program function, no object detected

    Electrical specifications

    Operating voltage UB10 ... 30 V DC , ripple 10 %SS
    No-load supply current I0≤ 50 mA

    Output

    Output type1 analog output 0-10V or 4…20mA.
    ResolutionEvaluation range [mm]/4000, but ≥0.35mm
    Deviation of the characteristic curve≤0.2% from full-scale value
    Repeat accuracy± 0.1 % of full-scale value
    Load impedance>1k Ohm
    Temperature influence≤ 2 % of full-scale value

    Ambient conditions

    Ambient temperature-25 ... 70 °C
    Storage temperature-40 ... 85 °C

    Mechanical specifications

    Connection typeDevice connector M12 x 1 , 4-pin
    Protection gradeIP65 (IP67 selectable)
    MaterialHousing: nickel plated brass or plastic

    LED Displays


    Displays in dependence on operating modeRed LEDYellow LED

    TEACH-IN evaluation limit

    Object detected

    No object detected

    Object uncertain (TEACH-IN invalid)


    off

    flashes

    on


    flashes

    off

    off

    Normal mode (evaluation range)offon
    Faultonprevious state

    Installation conditions


    If the sensor is installed at the environment temperature fall below 0℃,It should do well on the protective measures. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread.


    Sensor Function Description


    Set and adjust the switching point and advance interval of the switching output and analog output products

    Switching and analog output can be set using the tuning end, specifically, there are eight working modes that can be set.

    Each of these Settings is divided into the following steps:

    In the first step, the user selects a self-set distance or puts the sensor into the wave-loss state.

    Second, connect the calibration terminal to the power supply or GND, and keep the connection until the yellow light blinks (or the red light blinks if the state is lost).

    In the third step, the user selects the second self-set distance or allows the sensor to enter the wave loss state.

    In the fourth step, connect the calibration terminal to the GND or power supply (different state from the second step), and keep the connection until the yellow light blinks (or the red light blinks in the case of wave loss).


    There are 8 modes of switching output

    1. Window normally open mode (analog output products for positive linear working mode or distance measurement mode).

    2. Window normally closed mode (analog output product is negative linear operation mode or liquid level measurement mode).

    3. Single point normally on mode.

    4. Single-point normally closed mode.

    5. Single point normally open interval mode with large hysteresis loop.

    6. Single-point normally closed interval mode with large hysteresis loop.

    7. Whether the normally open mode is detected.

    8. Whether the normally closed mode is detected.

    About RS485 output model products. Description of

    There are three modes of operation,

    1: Automatic measurement mode, the sensor continuously measures the liquid level and distance, and the user reads the measurement results through the 485 interface at any time.

    2: The user does not initiate a 485 communication, the sensor will actively initiate a measurement and report the result.

    3: Sleep mode, the product goes into sleep mode, the user first wakes up the sensor through the 485 interface, and then initiates a measurement and obtains the results before the sensor sleeps again.


    Click here to learn more

    https://www.kacise.com/product/kus3000-m30-type1-series-ultrasonic-level-distance-sensor/?nowprocket=1

    Quality 3m Range 4 - 20mA Fluid Level Meter Small Diameter Ultrasonic Sensor For Industrial Automation for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)