    "Specs at a glance
    Max. measurement error
    Volume flow (liquid): ±0.75 %
    Volume flow (steam, gas): ±1.00 %
    Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
    Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation)
    Mass flow (liquid): ±0.85%

    Measuring range
    Liquid: 0.2 to 540 m³/h (0.15 to 320 ft³/min)
    depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
    Steam, gas: 1.5 to 7260 m³/h (0.9 to 4270 ft³/min)
    depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)

    Medium temperature range
    Standard: –40 to +260 °C (–40 to +500 °F)
    High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
    High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)

    Max. process pressure
    PN 40, Class 300, 20K

    Wetted materials
    Measuring tube: 1.4408 (CF3M)
    DSC sensor: 1.4404/F316/F316L
    Process connection: 1.4404/F316/F316L" "Field of application
    Prowirl R was designed for low flows and is thus the particularly dependable solution for energy management. Additionally its calibration option PremiumCal guarantees excellent measuring accuracy for maximum plant availability. With genuine loop-powered technology, Prowirl R 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology enables process safety at all times.

    Preferred measuring principle for wet/saturated/superheated steam, gases & liquids (also cryogenic)

    Dedicated to applications with very low or reduced flow


    Device properties

    Integrated diameter reduction by 1 or 2 line sizes

    Nominal diameter (mating pipe) up to DN 250 (10"")

    Flexible positioning of pressure cell

    Display module with data transfer function

    Robust dual-compartment housing

    Plant safety: worldwide approvals (SIL, Haz. area)" "Benefits
    Easy energy management – integrated temperature and pressure measurement for steam and gases

    Cost and time savings – no pipework modifications needed for line size reduction

    Same accuracy down to Re 10 000 – most linear Vortex meter body

    Long-term stability – robust drift-free capacitive sensor

    Convenient device wiring – separate connection compartment, various Ethernet options

    Safe operation – no need to open the device

    Integrated verification – Heartbeat Technology" "Measuring principle
    Vortex

    Product headline
    Flowmeter with best-in-class accuracy despite pipe reduction.
    Easy energy management – integrated temperature and pressure measurement for steam and gases.
    Dedicated to applications with very low flow or reduced flow.

    Sensor features
    Cost and time savings – no pipework modifications needed for line size reduction. Same accuracy down to Re 10 000 – most linear Vortex meter body. Long-term stability – robust drift-free capacitive sensor. Integrated diameter reduction by 1 or 2 line sizes. Nominal diameter (mating pipe) up to DN 250 (10"").

    Transmitter features
    Cost and time savings – no pipework modifications needed for line size reduction. Same accuracy down to Re 10 000 – most linear Vortex meter body. Long-term stability – robust drift-free capacitive sensor.
    Integrated diameter reduction by 1 or 2 line sizes. Nominal diameter (mating pipe) up to DN 250 (10""). Flexible positioning of pressure cell.

    Nominal diameter range
    DN 25 to 250 (1 to 10"")

    Wetted materials
    Measuring tube: 1.4408 (CF3M)
    DSC sensor: 1.4404/F316/F316L
    Process connection: 1.4404/F316/F316L

    Measured variables
    Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature

    Max. measurement error
    Volume flow (liquid): ±0.75 %
    Volume flow (steam, gas): ±1.00 %
    Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
    Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation)
    Mass flow (liquid): ±0.85%

    Measuring range
    Liquid: 0.2 to 540 m³/h (0.15 to 320 ft³/min)
    depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
    Steam, gas: 1.5 to 7260 m³/h (0.9 to 4270 ft³/min)
    depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)

    Max. process pressure
    PN 40, Class 300, 20K

    Medium temperature range
    Standard: –40 to +260 °C (–40 to +500 °F)
    High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
    High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)

    Ambient temperature range
    Compact version (standard): –40 to +80 °C (–40 to +176 °F)
    Compact version (option): –50 to +80 °C (–58 to +176 °F)
    Remote version (standard): –40 to +85 °C (–40 to +185 °F)
    Remote version (option): –50 to +85 °C (–58 to +185 °F)

    Sensor housing material
    Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)

    Transmitter housing material
    AlSi10Mg, coated; 1.4404 (316L)

    Degree of protection
    Compact version: IP66/67, type 4X enclosure
    Sensor remote version: IP66/67, type 4X enclosure
    Transmitter remote version: IP66/67, type 4X enclosure

    Display/Operation
    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible
    Remote display available

    Outputs
    4‐20 mA HART (passive)
    4‐20 mA (passive)
    Pulse/frequency/switch output (passive)

    Inputs
    4‐20 mA (passive)

    Digital communication
    HART, PROFIBUS PA, FOUNDATION Fieldbus, PROFINET over Ethernet-APL, Modbus TCP over Ethernet-APL

    Power supply
    DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
    DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
    DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
    DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)

    Hazardous area approvals
    ATEX, IECEx, cCSAus, JPN, EAC, UK Ex

    Product safety
    CE, C-tick, EAC

    Functional safety
    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

    Metrological approvals and certificates
    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

    Marine approvals and certificates
    ABS, LR, BV, DNV, CCS

    Pressure approvals and certificates
    PED, CRN, AD 2000

    Material certificates
    3.1 material
    NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614‐1, similar to ASME IX (on request)"