Sign In | Join Free | My burrillandco.com
Home > Ultrasonic Transducer Sensor >

Pointek CLS200 - Digital

    Buy cheap Pointek CLS200 - Digital from wholesalers
     
    Buy cheap Pointek CLS200 - Digital from wholesalers
    • Buy cheap Pointek CLS200 - Digital from wholesalers

    Pointek CLS200 - Digital

    Ask Lasest Price
    Brand Name : SIEMENS
    Model Number : CLS200 - Digital
    Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
    Supply Ability : 1000 Piece/Pieces per Week negotiable
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    Pointek CLS200 - Digital

    Pointek CLS200 - Digital
    Pointek CLS200 (digital version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces and has the ability to tune out buildup on the probe. The digital version includes PROFIBUS PA, an LCD display, and advanced diagnostic features.

    7ML5640-.....-....7ML5641-.....-....7ML5642-.....-....7ML5643-.....-....7ML5644-.....-....

    Related products

    Part NumberDescription
    7ML1830-1JBCABLE GLAND, 1/2" NPT, explosion proof
    7ML1830-1JCM20 x 1.5 cable gland (general use and dust explosion protection)
    7ML1830-1JDCABLE GLAND, M20 x 1.5 HF, (EP)
    7ML1830-1JETest Magnet
    7ML1830-1JFAMPLIFIER / POWER SUPPLY DIGITAL VERSION
    7ML1830-1JKLCD DISPLAY FOR CLS 200, DIGITAL
    A5E01163672Spare Synprene gasket, enclosure version, for IP65 versions
    A5E01163673Spare Silicone gasket, enclosure version, for IP68 version
    A5E01163674CLS200/CLS300/LC300 Spare aluminum blind lid, for standard versions
    A5E01163676CLS200/300 Spare aluminum lid with window
    A5E01163677Kit, sensor for cable units, PPS, standard, Viton
    A5E01163678Kit, sensor for cable units, PPS, digital, Viton
    A5E01163679Kit, sensor for cable units, PPS, standard, FFKM
    A5E01163680Kit, Sensor for cable units, PPS, Digital, FFKM
    A5E01163681Kit, Sensor for cable units, PVDF, Standard, FKM
    A5E01163682Kit, sensor for cable unit, PVDF, Digital, FKM
    A5E01163683Kit, sensor for cable unit, PVDF, Standard, FFKM
    A5E01163684Kit, sensor for cable unit, PVDF, Digital, FFKM
    A5E01163685Spare, 316L stainless steel mounting bracket
    A5E01163686Spare, PROFIBUS connector, IP65 versions only
    A5E03251681Kit, CLS200 standard, transmitter


    Benefits
    Potted construction protects signal circuit from shock, vibration, humidity, and/or condensation
    High chemical resistance
    Level detection independent of tank or pipe earth reference
    Insensitive to product buildup due to high frequency oscillation
    High sensitivity allows installation in a wide range of liquids, solids or slurry applications
    Integral LCD display allows for easy menu-driven setup
    PROFIBUS PA communication (SIMATIC PDM compatible)


    Application
    Pointek CLS200 digital version provides an integral LCD display for stand-alone use, and also provides PROFIBUS PA communication (Profile version 3.0, Class B) for connection to a network.

    The power supply is galvanically isolated and accepts a wide range of voltages (12 to 30 V DC). When used with thermal isolator, the stainless steel and PPS (PVDF optional) materials used in the probe construction provide a temperature rating up to 125 °C (257 °F) on the process wetted portion of the probe. The switch responds to any material with a dielectric constant of 1.5 or more by detecting a change in oscillating frequency, and it can be set to detect before contact or on contact with the probe. The menu-driven setup allows precise control of the switch point signal damping and alarm functions.

    When connected to the PROFIBUS network, advanced diagnostics and set up using SIMATIC PDM are possible.

    The CLS200 operates independently of the tank wall or pipe so it does not require an external reference electrode for level detection in a non-conductive vessel such as concrete or plastic (EMC regulations applicable in some regions).

    Key Applications: liquids, slurries, powders, granules, pressurized applications, hazardous areas


    Configuration

    Pointek CLS200 - Digital

    Pointek CLS200 - Digital

    Technical specifications

    Pointek CLS200 - Digital


    Mode of operation


    Measuring principle

    Inverse frequency shift capacitive level detection

    Input


    Measured variable

    Change in picoFarad (pF)

    Output


    Output signal


    • Solid-state output

    • Output

    Galvanically isolated

    • Protection

    Against reversed polarity (bipolar)

    • Max. switching voltage
    • 30 V (DC)
    • 30 V peak (AC)
    • Max. load current

    82 mA

    • Voltage drop

    < 1 V, typical at 50 mA

    • Time delay (ON and/or OFF)

    Programmable by user (0 ... 100 s)

    • Fail-safe mode

    Min. or max.

    • Connection

    Removable terminal block

    Rated operating conditions1)


    Installation conditions


    • Location

    Indoor/outdoor

    Ambient conditions


    • Ambient temperature

    ‑40 ... +85 °C (‑40 ... +185 °F)2)

    • Storage temperature

    ‑40 ... +85 °C (‑40 ... +185 °F)

    • Installation category

    II

    • Pollution degree

    4

    Medium conditions

    Liquids, bulk solids, slurries, and interfaces

    • Relative dielectric constant εr

    Min. 1.5

    • Process temperature

    • Without thermal isolator

    ‑40 ... +85 °C (‑40 ... +185 °F)2)

    • With thermal isolator

    ‑40 ... +125 °C (‑40 ... +257 °F)

    • Process pressure (rod version)

    ‑1 ... +25 bar g (‑14.6 ... +365 psi g) (nominal)

    • Process pressure (cable version)3)

    ‑1 ... +10 bar g (‑14.6 ... +150 psi g) (nominal)

    • Process pressure (sliding coupling version)

    ‑1 ... +10 bar g (‑14.6 ... +150 psi g) (nominal)

    Design


    Material


    • Enclosure

    Epoxy-coated aluminum with gasket

    • Optional thermal isolator

    316L stainless steel

    Connection

    Removable terminal block, max. 2.5 mm²

    Degree of protection

    IP65/Type 4/NEMA 4 (optional IP68)

    Cable inlet

    2 x M20 x 1.5 thread (option: 2 x ½" NPT conduit entry including 1 plugged entry)

    Electromagnetic compatibility

    To comply with CE EMC regulations (where applicable); the CLS200 should be installed per the instruction manual.

    Power supply


    Bus voltage

    Standard: 12 ... 30 V DC

    Intrinsically Safe: 12 ... 24 V DC

    Current consumption

    12.5 mA

    Certificates and approvals


    General Purpose

    CSA, FM, CE, UKCA, RCM

    Dust Ignition Proof

    ATEX II 1/2 D Ex ia/tb [ia Da]
    IIIC TX Da/Db,
    ATEX III 2(1) D Ex ia tb [ia Da]
    IIIC TX Db
    UKEX II 1/2 D Ex ia/tb [ia Da]
    IIIC TX Da/Db,
    UKEX III 2(1) D Ex ia tb [ia Da]
    IIIC TX Db

    Dust Ignition Proof with IS Probe

    CSA/FM Class II, Div. 1, Groups E, F, G
    CSA/FM Class III T4

    Flameproof Enclosure with IS Probe

    ATEX II 1/2 G Ex ia/db [ia Ga] IIC TX Ga/Gb,
    ATEX II 2(1) G Ex db ia [ia Ga] IIC TX Gb

    UKEX II 1/2 G Ex ia/db [ia Ga] IIC TX Ga/Gb,
    UKEX II 2(1) G Ex db ia [ia Ga] IIC TX Gb

    Explosion Proof with IS Probe

    CSA/FM Class I, Div. 1, Groups A, B, C, D
    CSA/FM Class II, Div. 1, Groups E, F, G
    CSA/FM Class III T4

    Intrinsically Safe4)

    ATEX II 1 G Ex ia IIC TX Ga,
    ATEX II 1/2 D Ex ia IIIC TX Da/Db,
    ATEX II 1 G Ex ia IIC TX Ga,
    ATEX II 2 D Ex ia IIIC TX Db,
    ATEX II 1 G Ex ia IIC TX Ga,
    ATEX II 1 D Ex ia IIIC TX Da,
    ATEX II 1/2 D Ex ia IIIC TX Da/Db

    UKEX II 1 G Ex ia IIC TX Ga,
    UKEX II 1/2 D Ex ia IIIC TX Da/Db,
    UKEX II 1 G Ex ia IIC TX Ga,
    UKEX II 2 D Ex ia IIIC TX Db,
    UKEX II 1 G Ex ia IIC TX Ga,
    UKEX II 1 D Ex ia IIIC TX Da,
    UKEX II 1/2 D Ex ia IIIC TX Da/Db

    Non-incendive

    CSA/FM Class I, Div. 2, Groups A, B, C, D
    CSA/FM Class II, Div. 2, Groups F, G
    CSA/FM Class III T4 or T6

    Non-Sparking

    ATEX II 3 G Ex ec IIC T6 ... T4
    ATEX II 2 D IP6X T100 °C

    UKEX II 3 G Ex ec IIC T6 ... T4
    UKEX II 2 D IP6x T100°C

    Marine

    Lloyds Register of Shipping, Categories ENV1, ENV2, and ENV5

    Others

    Pattern Approval (China)

    Communication

    PROFIBUS PA (IEC 61158 CPF3 CP3/2)
    Bus physical layer: IEC 61158-2 MBP (IS)
    Device profile: PROFIBUS PA profile for Process Control Devices Version 3.0, Class B FISCO field device