    SITRANS LCS100 is a point level switch that detects point level in liquids, solids, slurries, foam, and interface detection. Its compact design is ideal for confined spaces with plastic or stainless steel process connections and flexible rod and cable probe extensions. SITRANS LCS100 is used for overflow, high, low, and demand applications as well as pump protection. It works in all types of vessels, pipes, and silos in a broad range of industries including food, pharmaceuticals, chemical, petrochemical, water, and machine building.

    7ML700.-.....-....

    7ML701.-.....-....

    7ML702-.....-....

    7ML703.-.....-....

    Benefits
    Potted construction provides protection from shock and vibration
    Factory calibrated to work in most applications without tuning
    Active shield and tunable to compensate for build-up
    Optional IO-link communication and remote testing
    Options for plastic or Stainless steel enclosure and M12 connection

    Application
    SITRANS LCS100's flexible insertion length, starting at 92 mm (3.6 inch), and its versatility in various applications and in vessels or pipes make it a good fit for most point level applications.

    Its advanced design provides accurate, repeatable, switchpoint performance. The PPS (Polyphenylene sulfide) probe [optional PVDF (Polyvinylidene Fluoride)] and optional peek are chemically resistant with an effective process operating temperature range from ‑40 to +125 °C (‑40 to +257 °F). The fully potted design ensures reliability in a vibrating environment such as agitated tanks. When used with a SensGuard protection cover, the LCS100 is protected from shearing, impact, and abrasion in tough primary processes.

    The SITRANS LCS100 is available with either a stainless steel enclosure or a polyester enclosure and stainless steel or PPS process connection options.

    Key Applications: liquids, slurries, powders, granules, food and pharmaceuticals, chemicals, hazardous areas

    Configuration

    SITRANS LCS100

    Technical specifications


    Compact (7ML701 and 7ML700)

    Extended (7ML702 and 7ML703)

    Mode of Operation



    Measuring principle

    Capacitive level detection

    Capacitive level detection

    Input



    Measured variable

    Change in picoFarad (pF)

    Change in picoFarad (pF)

    Output



    Output signal



    • Alarm output

    8/16 mA or 4 ... 20 mA , 2-wire loop or IO-Link, PNP, NPN

    8/16 mA or 4 ... 20 mA, 2-wire loop or IO-Link, PNP, NPN *IO-Link not available with Cable version

    • Switch output

    4-wire relay (general purpose) or transistor (intrinsically safe)

    4-wire relay (general purpose) or transistor (intrinsically safe)

    • Fail-safe mode

    Min. or max.

    Min. or max.

    Accuracy



    Repeatability

    2 mm (0.08 inch)

    2 mm (0.08 inch)

    Rated operating conditions1)



    Installation conditions



    • Location

    Indoor and outdoor

    Indoor and outdoor

    Ambient conditions



    • Ambient temperature

    ‑40 ... +85 °C (‑40 ... +185 °F)

    ‑40 ... +85 °C (‑40 ... +185 °F)

    • Storage temperature

    ‑40 ... +80 °C (‑40 ... +176 °F)

    ‑40 ... +80 °C (‑40 ... +176 °F)

    • Installation category

    I

    I

    • Pollution degree

    4

    4

    Medium conditions



    • Relative dielectric constant εr

    Min. 1.5

    Min. 1.5

    • Process temperature – configuration dependent

    ‑40 ... +125 °C (‑40 ... +257 °F), see temperature curve

    ‑40 … +125 °C (‑40 ... +257 °F), see temperature curve

    • Pressure (vessel) – configuration dependent

    ‑1 ... 25 bar (363 psi) – Stainless Process connection

    ‑1 ... 25 bar (363 psi) - Rod extensions


    ‑1 ... 10 bar (146 psi) – PPS process connection

    ‑1 ... 10 bar (146 psi) - Cable extensions

    • Degree of protection


    • Enclosure Ø65 mm

    Type 4X/IP68

    Type 4X/IP68

    • Enclosure Ø35 mm

    Type 4X/IP68

    Not applicable

    • Cable inlet

    ½" NPT or M20 x 1.5

    ½" NPT or M20 x 1.5

    Device version



    Material



    • Body (enclosure version)

    Thermoplastic polyester

    Thermoplastic polyester

    • Lid (enclosure version)

    Transparent thermoplastic polycarbonate (PC)

    Transparent thermoplastic polycarbonate (PC)

    • Enclosure Ø35 mm

    316L stainless steel

    Not applicable

    Sensor length (nominal)

    92 mm (3.6 inch)

    300 ... 4 000 mm (11.8 … 157 inch) - Rod version

    400 ... 20 000 mm (15.7 ... 787 inch) - Cable version

    Process connection material of probe/wetted parts2)

    Connection: 316L stainless steel or PPS;
    Process seal: FKM (optional FFKM);
    Sensor: PEEK or PPS or PVDF

    Connection: 316L stainless steel or PPS;
    Process seal: FKM (optional FFKM);
    Sensor: PPS or PVDF
    Extension: Pipe 316L Cable: FEP jacketed

    Connection (Enclosure 65 mm)

    Terminal block, terminals 0.14 ... 1.5 mm2 (AWG 28 ... 16) or M12 x 1 according to IEC 61076-2-101, male, 4-pole, coding A-standard

    Terminal block, terminals 0.14 ... 1.5 mm2 (AWG 28 ... 16) or M12 x 1 according to IEC 61076-2-101, male, 4-pole, coding A-standard

    Connection (Enclosure 35 mm)

    M12 x 1 according to IEC 61076-2-101, male, 4-pole, coding A-standard

    Not applicable

    Process connection

    Thread: G ½", G ¾", G 1“, NPT ¾"

    Tri-clamp DN25 (1"), DN40 (1 1/2"), DN50 (2")

    DIN 32676 Type A (DIN 11851) and

    DIN 32676 Type C (ASME BPE 2009)

    Flange (screwed) DN 25, 40, 50; ASME 1", 1 ½”, 2"

    Thread: G ¾", G 1“, NPT ¾"

    Flange: DN 25, 40, 50; ASME 1", 1 ½”, 2"

    Adapters for G 1 ½", NPT 1 ¼", NPT 1 ½"

    Power supply



    Standard

    • 4-wire with relay supply:
      9 ... 33 V DC, 0.7W including 10 % of EN 61010-1
    • 2-wire with 8/16 or 4 ... 20 mA loop:
      9 ... 33 V DC, 0.7W including 10 % of EN 61010-1
    • IO-Link / PNP / NPN
      10 ... 30 V DC, incl. 10 % of EN 61010-1
    • 4-wire with relay supply:
      9 ... 33 V DC, 0.7W including 10 % of EN 61010-1
    • 2-wire with 8/16 or 4 ... 20 mA loop:
      9 ... 33 V DC, 0.7W including 10 % of EN 61010-1
    • IO-Link / PNP / NPN
      10 ... 30 V DC, incl. 10 % of EN 61010-1

    Intrinsically Safe

    • 2-wire with 8/16 or 4 ... 20 mA loop:
      10.8 ... 30 V DC, 0.7W incl. 10 % of
      EN 61010-1, intrinsically safe barrier required
    • 4-wire with relay:
      10.8 .... 30 V DC, 0.7W incl. 10 % of
      EN 61010-1, intrinsically safe barrier required
    • 2-wire with 8/16 or 4 ... 20 mA loop:
      10.8 ... 30 V DC, 0.7W incl. 10 % of
      EN 61010-1, intrinsically safe barrier required

    Certificates and approvals

    • General purpose: CE, UKCA, FM, CSA
    • ATEX II 1G, 1/2G Ex ia IIC
    • ATEX II 1D, 1/2D Ex ia IIIC
    • IEC Ex ia IIC
    • IEC Ex ia IIIC
    • FM/CSA IS Class I, II, III, Div. 1, Groups A ... G
    • Overfill protection: WHG (Germany) VLAREM
    • General purpose: CE, UKCA, FM, CSA
    • ATEX II 1G, 1/2G Ex ia IIC
    • ATEX II 1D, 1/2D Ex ia IIIC
    • IEC Ex ia IIC
    • IEC Ex ia IIIC
    • FM/CSA IS Class I, II, III, Div. 1, Groups A ... G
    • Overfill protection: WHG (Germany) VLAREM