Pointek CLS300 - Digital
Pointek CLS300 (digital version) is an inverse frequency shift
capacitance level and material detection switch with optional
rod/cable choices and configurable output. It is ideal for
detecting liquids, solids, slurries, foam, and interfaces in
demanding conditions where high pressure and temperatures are
present and has the ability to tune out buildup on the probe. The
digital version includes PROFIBUS PA, an LCD display, and advanced
diagnostic features.
![]() | ![]() | ![]() |
| 7ML5660-.....-.... CLS300,DIGITAL,ROD VERSN,THREAD/FLANGE | 7ML5661-.....-.... CLS300,DIGITAL,CABLE VERSN,THREAD/FLANGE | 7ML5662-.....-.... CLS300,DIGITL,HIGH TEMP ROD,THREAD/FLANG |
Related products
| Part Number | Description |
| 7ML1830-1AP | EASY AIMER II, ALUMINIUM, 3/4 INCH NPT WITH 1 INCH GALVANIZED COUPLING |
| 7ML1830-1JA | CABLE GLAND, 1/2" NPT, General Purpose DIP |
| 7ML1830-1JB | CABLE GLAND, 1/2" NPT, explosion proof |
| 7ML1830-1JC | M20 x 1.5 cable gland (general use and dust explosion protection) |
| 7ML1830-1JD | CABLE GLAND, M20 x 1.5 HF, (EP) |
| 7ML1830-1JE | Test Magnet |
| 7ML1830-1JF | AMPLIFIER / POWER SUPPLY DIGITAL VERSION |
| 7ML1830-1JK | LCD DISPLAY FOR CLS 200, DIGITAL |
| 7ML1930-1AQ | One metallic cable gland M20x1.5, rated -40掳C (-40掳F) to +80掳C (+176掳F) with integrated shield connection (available for PROFIBUS PA) |
| A5E01163688 | Kit, 316L stainless steel cable extension, 1 Meter, CLS300/LC300 |
| A5E01163689 | Kit, 316L stainless steel cable extension, 3 Meter, CLS300/LC300 |
| A5E01163690 | Kit, 316L stainless steel cable extension, 5 Meter, CLS300/LC300 |
| A5E01163691 | Kit, 316L stainless steel cable extension, 10 Meter, CLS300/LC300 |
| A5E01163693 | Kit, 316L stainless steel cable extension, 15 Meter, CLS300/LC300 |
| A5E01163695 | Kit, 316L stainless steel cable extension, 20 Meter, CLS300/LC300 |
| A5E01163698 | Kit, 316 stainless steel PFA cable extension, 3 METER, CLS300 |
| A5E01163699 | Kit, 316 stainless steel PFA cable extension, 5 METER, CLS300 |
| A5E01163700 | Kit, 316 stainless steel PFA cable extension, 10 METER, CLS300 |
| A5E01163701 | Kit, 316 stainless steel PFA cable extension, 15 METER, CLS300 |
| A5E01163702 | Kit, 316 stainless steel PFA cable extension, 20 METER, CLS300 |
| A5E01163719 | Kit, 316L stainless steel rod 180 mm (7.09") |
| A5E01163720 | Kit, 316L stainless steel rod 330 mm (12.99") |
| A5E01163721 | Kit, 316L stainless steel rod 580 mm (22.83") |
| A5E01163722 | Kit, 316L stainless steel rod 830 mm (32.68") |
| A5E01163723 | Replacement electronics with driver, CLS300 standard. For use with rod or Cable versions with maximum length of 5 m |
| A5E01163724 | Replacement electronics with driver, CLS300 standard. For use with Cable versions with minimum length of 5 m |
| A5E01163725 | Replacement electronics with driver, CLS300 Digital. For use with rod or Cable versions with maximum length of 5 m |
| A5E01163726 | Replacement electronics with driver, CLS300 Digital. For use with Cable versions with minimum length of 5 m |
| A5E01163727 | KIT, Spare 316L stainless steel weight, CLS/LC300, cable version |
| A5E03251683 | Kit, CLS300 standard, transmitter |
Benefits
Active-Shield technology so measurement is unaffected by material
buildup or nozzle interference in active shield section
Performs in extremely abrasive conditions because of solid rod
construction
Push-button calibration, full-function diagnostics
High sensitivity allows installation in a wide range of liquids,
solids or slurry applications
Integral LCD display allows for easy menu-driven setup
PROFIBUS PA communication (SIMATIC PDM compatible)
Application
Pointek CLS300 digital version provides an integral LCD display for
stand-alone use, with PROFIBUS PA communication
(Profile version 3.0, Class B) when required. Solid-state switch
alarm is standard.
The robust design of CLS300 makes it specifically applicable for heavy solids applications where abrasive materials occur as in the mining industry.
The fully potted electronics are unaffected by condensation, dust or vibration.
Wetted parts are made of stainless steel with a PFA shield for high chemical resistance, and of ceramic and stainless steel for high temperature version. Materials with low or high dielectric constants can be accurately detected. The unique Active Shield suppresses interference from material buildup or long installation nozzles.
The unique modular design of the Pointek CLS300 provides a wide range of configurations, process connections, extensions and approvals to meet the temperature and pressure requirements of specific applications. The modular design makes ordering easier and reduces stocking requirements. A wide range of probe configurations are available, including rod and cable versions.
Key Applications: liquids, slurries, bulk solids, relatively high pressure and temperature, hazardous areas, milling and mining applications
Configuration


Technical specifications
Pointek CLS300 Digital | |
|---|---|
Mode of operation | |
Measuring principle | Inverse frequency shift capacitive level detection |
Input | |
Measured variable | Change in picoFarad (pF) |
Output | |
Solid-state output | |
| Galvanically isolated |
| Against reversed polarity (bipolar) |
|
|
| 82 mA |
| < 1 V, typical at 50 mA |
| Programmable by user (0 ... 100 s) |
Fail-safe mode | Min. or max. |
Connection | Removable terminal block |
Accuracy | |
Resolution | |
| 1 % change in actual capacitance |
| 0.2 % of actual capacitance value |
Rated operating conditions1) | |
Installation conditions | |
| Indoor/outdoor |
Ambient conditions | |
| ‑40 ... +85 °C (‑40 ... +185 °F)2) |
| ‑40 ... +85 °C (‑40 ... +185 °F) |
Medium conditions | Liquids, bulk solids, slurries, interfaces, and applications with viscous materials |
| Min. 1.5 |
| |
| -40 ... +200 °C (-40 ... +392 °F)2) |
| -40 ... +400 °C (-40 ... +752 °F) |
| -1 ... +35 bar g (-14.6 ... +511 psi g) |
Design | |
Material (enclosure) | Powder-coated aluminum with gasket |
Degree of protection | Standard: Type 4/NEMA 4/IP65 |
Cable inlet | 2 x M20 x 1.5 thread (option: 2 x ½" NPT conduit entry including 1 plugged entry) |
Controls and displays | |
Local display | LCD |
Configuration |
|
Power supply | |
Bus voltage (at process connection) |
|
Current consumption | 12.5 mA |
Certificates and approvals | |
General Purpose | CSA, FM, CE, UKCA, RCM |
Dust Ignition Proof | ATEX II 1/2 D, 2 D IP6X T100 °C UKEX II 1/2 D Ex ia/tb [ia Da] IIIC TX |
Flameproof Enclosure With IS Probe | ATEX II 1/2 G EEx d[ia] IIC T6 ... T4 UKEX II 1/2 G Ex ia/db [ia Ga] IIC TX Ga/Gb |
Dust Ignition Proof With IS Probe | CSA/FM Class II, Div. 1, CSA/FM Class III T4 |
Intrinsically Safe4) | ATEX II 1 G EEx ia IIC T6 ... T4 UKEX II 1 G Ex ia IIC TX Ga CSA/FM Class I, Div. 1, |
Non-incendive | CSA/FM Class I, Div. 2, |
Explosion Proof with IS Probe | CSA/FM Class I, Div. 1, |
Marine | Lloyds Register of Shipping, Categories ENV1, ENV2, and ENV5 |
Others | Pattern Approval (China) |
Communication | PROFIBUS PA Bus physical layer: IEC 61158-2 MBP-(IS) Device profile: PROFIBUS PA profile for Process Control Devices Version 3.0, Class B FISCO field device |
|