    Proline Prowirl F 200 vortex flowmeter

    "Specs at a glance
    Max. measurement error
    Volume flow (liquid): ±0.75 %
    Volume flow (optional): ±0.65 %
    Volume flow (steam, gas): ±1.00 %
    Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
    Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation)
    Mass flow (liquid): ±0.85%

    Measuring range
    Liquid: 0.2 to 2100 m³/h (0.15 to 1520 ft³/min)
    depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
    Steam, gas: 1.5 to 28000 m³/h (0.9 to 16600 ft³/min)
    depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)

    Medium temperature range
    Standard: –40 to +260 °C (–40 to +500 °F)
    High/low temperature (option): –200 to +400 °C (–328 to +752 °F)

    Max. process pressure
    PN 100, Class 600, 20K

    Wetted materials
    Measuring tube: 1.4408 (CF3M); CX2MW similar to Alloy C22, 2.4602
    DSC sensor: 1.4404 (316/316L); UNS N06022 similar to Alloy C22, 2.4602
    Process connection: 1.4404/F316/F316L); 2.4602" "Field of application
    Prowirl F is the multivariable flowmeter with inline wet steam measurement. Its calibration option PremiumCal guarantees excellent measuring accuracy and highest plant availability at low flow rates of gas, steam and liquids. With genuine loop-powered technology, Prowirl F 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology enables process safety at all times.

    Preferred measuring principle for wet/saturated/superheated steam, gases & liquids (also cryogenic)

    Suitable for a wide range of applications; optimized for steam applications


    Device properties

    Wet steam capabilities for DN 25 to 300 (1 to 12"")

    Flexible positioning of pressure cell

    Industrial siphon design for pressure measurement

    Display module with data transfer function

    Robust dual-compartment housing

    Plant safety: worldwide approvals (SIL, Haz. area)" "Benefits
    Easy energy management – integrated temperature and pressure measurement for steam and gases

    Reliable, secure measurement technology – compliance with international Vortex standard ISO 12764

    Same accuracy down to Re 10 000 – most linear Vortex meter body

    Long-term stability – robust drift-free capacitive sensor

    Convenient device wiring – separate connection compartment, various Ethernet options

    Safe operation – no need to open the device

    Integrated verification – Heartbeat Technology" "Measuring principle
    Vortex

    Product headline
    Versatile flowmeter with detection of wet steam conditions and best-in-class accuracy.
    Easy energy management – integrated temperature and pressure measurement for steam and gases.
    Suitable for a wide range of applications; optimized for steam applications.

    Sensor features
    Space-saving engineering – inlet run compensation. Same accuracy down to Re 10 000 – most linear Vortex meter body. Long-term stability – robust drift-free capacitive sensor.
    Wet steam capabilities for DN 25 to 300 (1 to 12""). Flexible positioning of pressure cell. Industrial siphon design for pressure measurement.

    Transmitter features
    Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
    Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).

    Nominal diameter range
    DN 15 to 300 (½ to 12"")

    Wetted materials
    Measuring tube: 1.4408 (CF3M); CX2MW similar to Alloy C22, 2.4602
    DSC sensor: 1.4404 (316/316L); UNS N06022 similar to Alloy C22, 2.4602
    Process connection: 1.4404/F316/F316L); 2.4602

    Measured variables
    Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature

    Max. measurement error
    Volume flow (liquid): ±0.75 %
    Volume flow (optional): ±0.65 %
    Volume flow (steam, gas): ±1.00 %
    Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
    Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation)
    Mass flow (liquid): ±0.85%

    Measuring range
    Liquid: 0.2 to 2100 m³/h (0.15 to 1520 ft³/min)
    depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
    Steam, gas: 1.5 to 28000 m³/h (0.9 to 16600 ft³/min)
    depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)

    Max. process pressure
    PN 100, Class 600, 20K

    Medium temperature range
    Standard: –40 to +260 °C (–40 to +500 °F)
    High/low temperature (option): –200 to +400 °C (–328 to +752 °F)

    Ambient temperature range
    Compact version (standard): –40 to +80 °C (–40 to +176 °F)
    Compact version (option): –50 to +80 °C (–58 to +176 °F)
    Remote version (standard): –40 to +85 °C (–40 to +185 °F)
    Remote version (option): –50 to +85 °C (–58 to +185 °F)

    Sensor housing material
    Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)

    Transmitter housing material
    AlSi10Mg, coated; 1.4404 (316L)

    Degree of protection
    Compact version: IP66/67, type 4X enclosure
    Sensor remote version: IP66/67, type 4X enclosure
    Transmitter remote version: IP66/67, type 4X enclosure

    Display/Operation
    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible
    Remote display available

    Outputs
    4‐20 mA HART (passive)
    4‐20 mA (passive)
    Pulse/frequency/switch output (passive)

    Inputs
    Current Input 4‐20 mA (passive)

    Digital communication
    HART, PROFIBUS PA, FOUNDATION Fieldbus, PROFINET over Ethernet-APL, Modbus TCP over Ethernet-APL

    Power supply
    DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
    DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
    DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
    DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)

    Hazardous area approvals
    ATEX, IECEx, cCSAus, JPN, EAC

    Product safety
    CE, C-TICK, EAC, UK Ex

    Functional safety
    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

    Metrological approvals and certificates
    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

    Marine approvals and certificates
    ABS, LR, BV, DNV, CCS

    Pressure approvals and certificates
    PED, CRN, AD 2000

    Material certificates
    3.1 material
    NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614‐1, similar to ASME IX (on request)"

    Quality Proline Prowirl F 200 vortex flowmeter for sale