    Proline Prowirl D 200 vortex flowmeter

    "Specs at a glance
    Max. measurement error
    Volume flow (liquid): ±0.75 %
    Volume flow (steam, gas): ±1.00 %
    Mass flow (liquid): ±0.85%
    Mass flow (steam, gas): ±1.7 %

    Measuring range
    Liquid: 0.25 to 625 m³/h (0.15 to 365 ft³/min)
    depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
    Steam, gas: 2.1 to 8335 m³/h (1.2 to 4906 ft³/min)
    depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)

    Medium temperature range
    Standard: –40 to +260 °C (–40 to +500 °F)
    High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
    High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)

    Max. process pressure
    PN 40, Class 300, 20K

    Wetted materials
    Measuring tube: 1.4408 (CF3M)
    DSC sensor: 1.4435 (316/316L)" "Field of application
    The Prowirl D sensor can be installed directly between flanges and thus serves as the functional device for applications in ancillary processes at little installation cost. With genuine loop-powered technology, Prowirl D 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology enables process safety at all times.

    Preferred measuring principle for wet/saturated/superheated steam, gases & liquids (also cryogenic)

    For all basic applications and for 1-to-1 replacement of orifice plates.

    Device properties

    Face-to-face length of 65 mm (2.56 in)

    No flanges

    Low weight

    Display module with data transfer function

    Robust dual-compartment housing

    Plant safety: worldwide approvals (SIL, Haz. area)" "Benefits
    Integrated temperature measurement for mass/energy flow of saturated steam

    Easy alignment of the sensor – included centering rings

    High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer

    Long-term stability – robust drift-free capacitive sensor

    Convenient device wiring – separate connection compartment

    Safe operation – no need to open the device due to display with touch control, background lighting

    Integrated verification – Heartbeat Technology" "Measuring principle
    Vortex

    Product headline
    Cost-effective wafer flowmeter, available as compact or remote version.
    Integrated temperature measurement for mass/energy flow of saturated steam.
    For all basic applications and for 1-to-1 replacement of orifice plates.

    Sensor features
    Easy alignment of the sensor – included centering rings. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. Long-term stability – robust drift-free capacitive sensor.
    Face-to-face length of 65 mm (2.56 in). No flanges. Low weight.

    Transmitter features
    Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
    Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).

    Nominal diameter range
    DN 15 to 150 (½ to 6"")

    Wetted materials
    Measuring tube: 1.4408 (CF3M)
    DSC sensor: 1.4435 (316/316L)

    Measured variables
    Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature

    Max. measurement error
    Volume flow (liquid): ±0.75 %
    Volume flow (steam, gas): ±1.00 %
    Mass flow (liquid): ±0.85%
    Mass flow (steam, gas): ±1.7 %

    Measuring range
    Liquid: 0.25 to 625 m³/h (0.15 to 365 ft³/min)
    depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
    Steam, gas: 2.1 to 8335 m³/h (1.2 to 4906 ft³/min)
    depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)

    Max. process pressure
    PN 40, Class 300, 20K

    Medium temperature range
    Standard: –40 to +260 °C (–40 to +500 °F)
    High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
    High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)

    Ambient temperature range
    Compact version (standard): –40 to +80 °C (–40 to +176 °F)
    Compact version (option): –50 to +80 °C (–58 to +176 °F)
    Remote version (standard): –40 to +85 °C (–40 to +185 °F)
    Remote version (option): –50 to +85 °C (–58 to +185 °F)

    Sensor housing material
    Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)

    Transmitter housing material
    AlSi10Mg, coated; 1.4404 (316L)

    Degree of protection
    Compact version: IP66/67, type 4X enclosure
    Sensor remote version: IP66/67, type 4X enclosure
    Transmitter remote version: IP66/67, type 4X enclosure

    Display/Operation
    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible
    Remote display available

    Outputs
    4‐20 mA HART (passive)
    4‐20 mA (passive)
    Pulse/frequency/switch output (passive)

    Inputs
    Current input 4‐20 mA (passive)

    Digital communication
    HART, PROFIBUS PA, FOUNDATION Fieldbus, PROFINET over Ethernet-APL, Modbus TCP over Ethernet-APL

    Power supply
    DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
    DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
    DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
    DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)

    Hazardous area approvals
    ATEX, IECEx, cCSAus, JPN, EAC, UK Ex

    Product safety
    CE, C-TICK, EAC

    Functional safety
    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

    Metrological approvals and certificates
    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

    Marine approvals and certificates
    ABS, LR, BV, DNV, CCS

    Pressure approvals and certificates
    PED, CRN

    Material certificates
    3.1 material
    NACE MR0175/MR0103, PMI (on request)"