"Specs at a glance
Max. measurement error
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
Measuring range
0.06 dm³/min to 600 m³/h (0.015 to 2650 gal/min)
Medium temperature range
–20 to +150 °C (–4 to +302 °F)
Max. process pressure
PN 40, Class 150, 20K
Wetted materials
Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC
adhesive sleeve
Seals: aseptic molded seal (EPDM, FKM, silicone)" "Field of
application
Promag H is the preferred sensor for hygienic applications in the
food and beverage and life sciences industries. With its
straightforward hard- and software design, Promag H 10 simplifies
every step in its life cycle from engineering to servicing at usual
Endress+Hauser quality. Heartbeat Technology enables measurement
reliability and extension of recalibration cycles.
The bidirectional measuring principle is virtually independent of
pressure, density, temperature and viscosity.
For applications with sanitary requirements
Device properties
Liner made of PFA
Sensor housing made of stainless steel (3-A, EHEDG)
Wetted materials CIP-/SIP-cleanable
System integration with HART, Modbus RS485, IO-Link
Flexible operation with app and optional display" "Benefits
Easy integration into your plant infrastructure with IO-link
Flexible installation concept – numerous hygienic process
connections
Energy-saving flow measurement – no pressure loss due to cross
section constriction
Maintenance-free – no moving parts
Optimum usability – display with touch screen (HART and Modbus
RS485 communication only) or operation with mobile devices and
SmartBlue app
Simple, time-saving commissioning – guided parameterization in
advance and in the field
Integrated verification – Heartbeat Technology" "Measuring
principle
Electromagnetic
Product headline
Flowmeter for basic hygienic applications with easy-to-use
operation concept.
For applications with sanitary requirements.
Sensor features
Flexible installation concept – numerous hygienic process
connections. Energy-saving flow measurement – no pressure loss due
to cross section constriction. Maintenance-free – no moving parts.
Liner made of PFA. Sensor housing made of stainless steel (3-A,
EHEDG). Wetted materials CIP-/SIP-cleanable.
Transmitter features
Optimum usability – display with touch screen (HART and Modbus
RS485 communication only) or operation with mobile devices and
SmartBlue app. Simple, time-saving commissioning – guided
parameterization in advance and in the field. Integrated
verification – Heartbeat Technology.
System integration with HART, Modbus RS485, IO-Link. Flexible
operation with app and optional display.
Nominal diameter range
DN 2 to 150 (¹⁄₁₂ to 6)
Wetted materials
Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC
adhesive sleeve
Seals: aseptic molded seal (EPDM, FKM, silicone)
Measured variables
Volume flow, temperature, conductivity, mass flow, corrected volume
flow, corrected
conductivity
Max. measurement error
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
Measuring range
0.06 dm³/min to 600 m³/h (0.015 to 2650 gal/min)
Max. process pressure
PN 40, Class 150, 20K
Medium temperature range
–20 to +150 °C (–4 to +302 °F)
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
Sensor housing material
1.4301 (304), corrosion resistant
Transmitter housing material
AlSi10Mg, coated
Degree of protection
Standard: IP66/67, type 4X enclosure
Display/Operation
2.4 LCD display with touch & auto rotate; Configuration and
operation via Bluetooth technology possible
Outputs
4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA
Digital communication
HART, MODBUS RS485, IO-Link
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals
CSA, GP, KC
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to
ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement
traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV
SÜD attestation)
Pressure approvals and certificates
PED, CRN
Material certificates
3.1 material
Hygienic approvals and certificates
Sanitary approval: EHEDG, 3-A, liner and seals acc. to FDA, cGMP"