Sign In | Join Free | My burrillandco.com
Home > Electromagnetic Flow Meter >

Proline Promag P 200 electromagnetic flowmeter

    Buy cheap Proline Promag P 200 electromagnetic flowmeter from wholesalers
     
    Buy cheap Proline Promag P 200 electromagnetic flowmeter from wholesalers
    • Buy cheap Proline Promag P 200 electromagnetic flowmeter from wholesalers

    Proline Promag P 200 electromagnetic flowmeter

    Ask Lasest Price
    Brand Name : Endress+Hauser
    Certification : CE
    Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
    Supply Ability : 1000 Piece/Pieces per Week negotiable
    Delivery Time : 5-8 work days
    Model Number : Proline Promag P 200
    • Product Details
    • Company Profile

    Proline Promag P 200 electromagnetic flowmeter

    "Specs at a glance
    Max. measurement error
    Volume flow: ±0.5 % o.r. ± 2 mm/s (0.08 in/s)
    Measuring range
    4 dm3/min to 1100 m3/h (1 to 4850 gal/min)
    Medium temperature range
    Liner material PFA: –20 to +150 °C (–4 to +302 °F)
    Liner material PTFE: –40 to +130 °C (–40 to +266 °F)
    Max. process pressure
    PN 40, Class 300, 20K
    Wetted materials
    Liner: PFA; PTFE
    Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum" "Field of application
    Promag P is dedicated to chemical and process applications with corrosive liquids and high medium temperatures. With genuine loop-powered technology, Promag P 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas thanks to its intrinsically safe design (Ex ia). Heartbeat Technology enables process safety at all times.
    The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
    Dedicated to chemical and process applications with corrosive liquids and high medium temperatures
    Device properties
    Nominal diameter: max. DN 200 (8"")
    All common Ex approvals
    Liner made of PTFE or PFA
    Loop-powered technology
    Robust two-chamber housing
    Plant safety: worldwide approvals (SIL, Haz. area)" "Benefits
    Versatile applications – wide variety of wetted materials
    Energy-saving flow measurement – no pressure loss due to cross-section constriction
    Maintenance-free – no moving parts
    Convenient device wiring – separate connection compartment
    Safe operation – no need to open the device due to display with touch control, background lighting
    Integrated verification – Heartbeat Technology" "Measuring principle
    Electromagnetic
    Product headline
    The flowmeter for highest medium temperatures with genuine loop-powered technology.
    Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.
    Sensor features
    Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
    Nominal diameter: max. DN 200 (8""). All common Ex approvals. Liner made of PTFE or PFA.
    Transmitter features
    Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
    Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
    Nominal diameter range
    DN 15 to 200 (½ to 8"")
    Wetted materials
    Liner: PFA; PTFE
    Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum
    Measured variables
    Volume flow, mass flow
    Max. measurement error
    Volume flow: ±0.5 % o.r. ± 2 mm/s (0.08 in/s)
    Measuring range
    4 dm3/min to 1100 m3/h (1 to 4850 gal/min)
    Max. process pressure
    PN 40, Class 300, 20K
    Medium temperature range
    Liner material PFA: –20 to +150 °C (–4 to +302 °F)
    Liner material PTFE: –40 to +130 °C (–40 to +266 °F)
    Ambient temperature range
    Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
    Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)
    Sensor housing material
    AlSi10Mg, coated
    Transmitter housing material
    AlSi10Mg, coated
    Degree of protection
    IP66/67, type 4X enclosure
    Display/Operation
    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible
    Remote display available
    Outputs
    4‐20 mA HART (passive)
    Pulse/frequency/switch output (passive)
    Inputs
    None
    Digital communication
    HART, PROFIBUS PA, FOUNDATION Fieldbus
    Power supply
    DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
    Hazardous area approvals
    ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, JPN, UK Ex
    Other approvals and certificates
    Product safety
    CE, C-Tick
    Functional safety
    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
    Metrological approvals and certificates
    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
    Pressure approvals and certificates
    CRN, PED
    Material certificates
    3.1 material
    Hygienic approvals and certificates
    Drinking water approvals: ACS, NSF 61"
    Quality Proline Promag P 200 electromagnetic flowmeter for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)