    Proline Promag P 100 electromagnetic flowmeter

    "Specs at a glance
    Max. measurement error
    Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
    Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s
    Measuring range
    4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)
    Medium temperature range
    Liner material PFA: –20 to +150 °C (–4 to +302 °F)
    Liner material PFA high‐temperature: –20 to +180 °C (–4 to +356 °F)
    Liner material PTFE: –40 to +130 °C (–40 to +266 °F)
    Max. process pressure
    PN 40, Class 300, 20K
    Wetted materials
    Liner: PFA, PTFE
    Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium
    Duplex 1.4462 (UNS S31803)" "Field of application
    Promag P is dedicated to chemical and process applications with corrosive liquids and high medium temperatures. Its ultra-compact transmitter delivers full performance on the smallest footprint and enables seamless system integration, making Promag P 100 the preferred choice for skid builders, equipment manufacturers and system integrators. Heartbeat Technology enables compliance and process safety at all times.
    The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
    Dedicated to chemical and process applications with corrosive liquids and high medium temperatures
    Device properties
    Nominal diameter: max. DN 600 (24"")
    All common Ex approvals
    Liner made of PTFE or PFA
    Robust, ultra-compact transmitter housing
    Local display available" "Benefits
    Versatile applications – wide variety of wetted materials
    Energy-saving flow measurement – no pressure loss due to cross-section constriction
    Maintenance-free – no moving parts
    Space-saving transmitter – full functionality on the smallest footprint
    Time-saving local operation without additional software and hardware – integrated web server
    Integrated verification – Heartbeat Technology" "Measuring principle
    Electromagnetic
    Product headline
    The flowmeter for highest medium temperatures with an ultra-compact transmitter.
    Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.
    Sensor features
    Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
    Nominal diameter: max. DN 600 (24""). All common Ex approvals. Liner made of PTFE or PFA.
    Transmitter features
    Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
    Robust, ultra-compact transmitter housing. Local display available.
    Nominal diameter range
    DN 15 to 600 (½ to 24"")
    Wetted materials
    Liner: PFA, PTFE
    Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium
    Duplex 1.4462 (UNS S31803)
    Measured variables
    Volume flow, conductivity, mass flow, corrected volume flow, corrected conductivity
    Max. measurement error
    Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
    Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s
    Measuring range
    4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)
    Max. process pressure
    PN 40, Class 300, 20K
    Medium temperature range
    Liner material PFA: –20 to +150 °C (–4 to +302 °F)
    Liner material PFA high‐temperature: –20 to +180 °C (–4 to +356 °F)
    Liner material PTFE: –40 to +130 °C (–40 to +266 °F)
    Ambient temperature range
    Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
    Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)
    Sensor housing material
    DN 15 to 300 (½ to 12""): AlSi10Mg, coated
    DN 350 to 600 (14 to 24""): Carbon steel with protective varnish
    Transmitter housing material
    AlSi10Mg, coated
    Degree of protection
    IP66/67, type 4X enclosure
    Display/Operation
    4‐line backlit display available (no local operation)
    Configuration via web browser and operating tools possible
    Outputs
    4‐20 mA HART (active)
    Pulse/frequency/switch output (passive)
    Inputs
    None
    Digital communication
    HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET
    Power supply
    DC 20 to 30 V
    Hazardous area approvals
    ATEX, IECEx, cCSAus, INMETRO
    Other approvals and certificates
    Product safety
    CE, C-Tick
    Metrological approvals and certificates
    Calibration performed on accredited calibration facilities (acc. to ISO/IEC
    17025)
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
    Marine approvals and certificates
    LR approval, DNV approval, ABS approval, BV approval
    Pressure approvals and certificates
    PED, CRN
    Material certificates
    3.1 material
    Hygienic approvals and certificates
    Drinking water approval: ACS, NSF 61, WRAS"