    Proline Promag P 500 electromagnetic flowmeter

    "Specs at a glance
    Max. measurement error
    Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
    Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec
    Measuring range
    4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min)
    Medium temperature range
    Liner material PFA: –20 to +150 °C (–4 to +302 °F)
    Liner material PFA high-temperature: –20 to +180 °C (–4 to +356 °F)
    Liner material PTFE: –40 to +130 °C (–40 to +266 °F)
    Max. process pressure
    PN 40, Class 300, 20K
    Wetted materials
    Liner: PFA; PTFE
    Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum;
    Titanium; Duplex 1.4462 (UNS S31803)" "Field of application
    Promag P is dedicated to chemical and process applications with corrosive liquids and highest medium temperatures. With its innovative remote transmitter Promag P 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables compliance and process safety at all times.
    The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
    Dedicated to chemical and process applications with corrosive liquids and high medium temperatures
    Device properties
    Nominal diameter: max. DN 600 (24"")
    All common Ex approvals
    Liner made of PTFE or PFA
    Remote version with up to 4 I/Os
    Backlit display with touch control and WLAN access
    Standard cable between sensor and transmitter" "Benefits
    Diverse applications – wide variety of wetted materials
    Energy-saving flow measurement – no pressure loss due to cross-section constriction
    Maintenance-free – no moving parts
    Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
    Reduced complexity and variety – freely configurable I/O functionality
    Integrated verification – Heartbeat Technology" "Measuring principle
    Electromagnetic
    Product headline
    High-temperature flowmeter for process applications as remote version with up to 4 I/Os.
    Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.
    Sensor features
    Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
    Nominal diameter: max. DN 600 (24""). All common Ex approvals. Liner made of PTFE or PFA.
    Transmitter features
    Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
    Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
    Nominal diameter range
    DN 15 to 600 (½ to 24"")
    Wetted materials
    Liner: PFA; PTFE
    Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum;
    Titanium; Duplex 1.4462 (UNS S31803)
    Measured variables
    Volume flow, conductivity, mass flow
    Max. measurement error
    Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
    Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec
    Measuring range
    4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min)
    Max. process pressure
    PN 40, Class 300, 20K
    Medium temperature range
    Liner material PFA: –20 to +150 °C (–4 to +302 °F)
    Liner material PFA high-temperature: –20 to +180 °C (–4 to +356 °F)
    Liner material PTFE: –40 to +130 °C (–40 to +266 °F)
    Ambient temperature range
    Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
    Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)
    Sensor housing material
    DN 15 to 300 (½ to 12""): AlSi10Mg, coated
    DN 350 to 600 (14 to 24""): Carbon steel with protective varnish
    Sensor connection housing (standard): AlSi10Mg, coated
    Sensor connection housing (option): 1.4409 (CF3M) similar to 316L
    Transmitter housing material
    AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
    Degree of protection
    Sensor remote version (standard): IP66/67, type 4X enclosure
    Transmitter remote version: IP66/67, Type 4X enclosure
    Display/Operation
    4-line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible
    Outputs
    4 outputs:
    4-20 mA HART (active/passive)
    4-20 mA WirelessHART
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Double pulse output (active/passive)
    Relay output
    Inputs
    Status input
    4-20 mA input
    Digital communication
    HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Modbus TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
    Power supply
    DC 24 V
    AC 100 to 230 V
    AC 100 to 230 V / DC 24 V (non-hazardous area)
    Hazardous area approvals
    ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC; JPN, UK Ex, KC
    Product safety
    CE, C-tick, EAC marking
    Functional safety
    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
    Metrological approvals and certificates
    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
    Marine approvals and certificates
    LR approval, DNV approval, ABS approval, BV approval
    Pressure approvals and certificates
    PED, CRN
    Material certificates
    3.1 material
    Hygienic approvals and certificates
    ACS, NSF 61, WRAS"