High Temperature And High Pressure Corrosion Resistant Capacitive Level Sensor For Boiler Level Monitoring

    Buy cheap High Temperature And High Pressure Corrosion Resistant Capacitive Level Sensor For Boiler Level Monitoring from wholesalers
     
    Buy cheap High Temperature And High Pressure Corrosion Resistant Capacitive Level Sensor For Boiler Level Monitoring from wholesalers
    • Buy cheap High Temperature And High Pressure Corrosion Resistant Capacitive Level Sensor For Boiler Level Monitoring from wholesalers
    • Buy cheap High Temperature And High Pressure Corrosion Resistant Capacitive Level Sensor For Boiler Level Monitoring from wholesalers
    • Buy cheap High Temperature And High Pressure Corrosion Resistant Capacitive Level Sensor For Boiler Level Monitoring from wholesalers

    High Temperature And High Pressure Corrosion Resistant Capacitive Level Sensor For Boiler Level Monitoring

    Ask Lasest Price
    Brand Name : KACISE
    Model Number : KSLV605
    Certification : CE
    Price : Dollar+56~256+USD
    Payment Terms : D/A,D/P,T/T,Western Union,MoneyGram,L/C
    Supply Ability : 1000 Piece/Pieces per Week negotiable
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    High Temperature And High Pressure Corrosion Resistant Capacitive Level Sensor For Boiler Level Monitoring

    High Temperature And High Pressure Corrosion Resistant Capacitive Level Sensor For Boiler Level Monitoring
    Product Specifications
    AttributeValue
    Measuring range0.1~3m
    Pressure range-0.1MPa~32MPa
    Capacitance detection range10PF~500PF
    Supply voltage5~36 V DC
    Output signal4-20mA/RS485
    Measurement accuracyLevel 0.1、0.2 、0.5 、1
    Environment temperature-40~85℃
    Ranging resolution0.1mm
    Long stability≤0.1%FS/ year
    Protection classIP67
    Product Description
    General Description

    The High Temperature and High Pressure Corrosion Resistant Capacitive Level Sensor is specifically engineered for boiler level monitoring applications. Designed to withstand extreme conditions, this sensor delivers reliable and accurate level measurement in high-temperature, high-pressure boiler systems. Its corrosion-resistant construction ensures long-term performance while maintaining operational safety and efficiency through precise real-time level data.

    Key Features
    • Modbus protocol for easy system integration
    • Simple, maintenance-free design with no moving or elastic components
    • Multiple signal output options for flexible system configuration
    • Accurate measurement unaffected by temperature, liquid specific gravity, or container shape/pressure
    • Ideal for measuring strong corrosive liquids including acids and alkalis
    • Comprehensive overcurrent, overvoltage, and power supply polarity protection
    • Optional wireless remote transmission capability
    • Compatible with any liquid medium
    Technical Specifications
    • Detection range: 0.1~3m
    • Capacitance measurement range: 10PF~500PF
    • Accuracy: 0.1 class, 0.2 class, 0.5 class, 1 class
    • Pressure range: -0.1MPa~32MPa
    • Probe temperature resistance: -50~250℃
    • Ambient temperature: -40~85℃
    • Storage temperature: -55℃~+125℃
    • Output signal: 4~20mA, 485 communication
    • Wireless communication distance: <200 meters (optional battery power supply 3.3-36V)
    • Power supply voltage: 5~36V DC
    • Material: 316 stainless steel, 1Gr18Ni19Ti or PTFE
    • Long-term stability: ≤0.1%FS/year
    • Temperature drift: ≤0.01%FS/℃ (0~70℃ range)
    • Explosion-proof grade: ExibIICT6
    • Protection level: IP67
    Product Structure

    The capacitive liquid level sensor consists of two main components: the sensor probe and transmitter. The structure varies based on application requirements.

    Capacitive level sensor structure diagram showing sensor probe, transmitter, and connection components

    A: Sensor probe that extends into the container or measuring tube

    B & C: Gas phase and liquid phase connection flanges for equipment interface

    D: Measuring cylinder that forms capacitance with the sensor electrode

    E: Drain flange for periodic cleaning to maintain measurement accuracy

    F: Transmitter that converts capacitance changes to 4-20mADC standard signal

    Important: The sealing section between transmitter and measuring tube contains critical seals. Do not disassemble without manufacturer approval to prevent leaks or accidents.
    Display Interface
    Display model KSLV606 showing liquid level measurement interface
    Wiring Configuration

    The KSLV606 display model supports two wiring methods:

    RS485 Connection:

    RS485 wiring diagram for capacitive level sensor

    4-20mA Connection:

    Isolated 4-20mA output wiring diagram Non-isolated 4-20mA 2-wire output wiring diagram

    Installation Note: Always open the gas phase valve first, followed by the liquid phase valve to prevent measurement errors from liquid level fluctuations. Ensure cable connections are secure and corrosion-resistant. Regular maintenance includes periodic draining (1-2 times weekly for dirty media, monthly for cleaner media).

    Common transmitter wiring methods:

    Direct transmitter to digital display meter wiring diagram Transmitter to DCS control system wiring diagram Transmitter powered by safety barrier wiring diagram
    Installation Guide

    Standard Installation:

    Gas phase and liquid phase installation diagram for level sensor

    Connect the gas-liquid phase flanges to equipment flanges with gaskets and bolts. Ensure outlet pipes are clean and sealing surfaces intact before installation.

    Note: Add valves between instrument and equipment flanges for easier maintenance.

    Boiler-Specific Installation:

    Boiler type capacitive level meter installation diagram

    Special heat-dissipating structure protects transmitter from high temperatures. Ensure correct orientation with transmitter positioned below.

    Calibration Procedure
    External liquid level measurement control instrument calibration setup
    1. Prepare transparent pipe with scale, precision ammeter, rubber stoppers, and test medium
    2. Connect pipe to liquid phase port, block drain, keep gas phase open, and connect ammeter
    3. Add medium at 0%, 25%, 50%, 75%, and 100% levels, comparing ammeter readings to expected 4mA, 8mA, 12mA, 16mA, and 20mA outputs
    Trouble Guide

    Display shows zero: Check 24V power supply, transmitter for shorts or quality issues

    Current below 4mA: Verify liquid level position, transmitter adjustment, or potential defects

    Current exceeds 25mA: Check for transmitter circuit shorts or excessive current adjustment

    Display fluctuations: Examine actual liquid level stability, connection quality, or transmitter issues

    No display change: Test transmitter functionality and check for pipe blockages or connection breaks

    Slow response: Clean sensor from impurities or check for partial gas phase blockage

    Measurement Tip: Always test 24V power supply by connecting voltmeter to power line terminals.

    Important Precautions
    1. Verify product documentation before installation
    2. Ensure interface compatibility with equipment
    3. Follow wiring instructions precisely
    4. Handle with care - avoid disassembly or impact
    5. Stop use and investigate any abnormalities
    6. Store in original packaging in cool, dry conditions
    7. Protect sensor from damage during handling
    8. Implement lightning protection measures
    9. Ground transmitter casing (resistance <4Ω)
    10. Use certified safety barriers for 485 communication
    11. Follow safety barrier installation requirements
    12. Use appropriate power transformers in hazardous areas
    Product Selection Guide
    KSLV Selection Table for Intelligent Capacitive Fluid Level Gauge
    Product Type605 (No display model)
    606 (No display model)
    Output Signal4-20mA signal output with LED display
    RS485 output
    Measuring RangeL500 (500mm)
    L800 (800mm)
    L1000 (1000mm)
    Lxxx (Custom lengths)
    Measuring MediaWater, diesel, or other specified media
    Example ConfigurationKSLV 605 4-20mA L800 water NA