Sign In | Join Free | My burrillandco.com
Home > Radar Level Transmitter >

High Integration KLM800 Radar Level Sensor Module with ±2.75° Antenna Beam Width and 10m Measurement Range

    Buy cheap High Integration KLM800 Radar Level Sensor Module with ±2.75° Antenna Beam Width and 10m Measurement Range from wholesalers
     
    Buy cheap High Integration KLM800 Radar Level Sensor Module with ±2.75° Antenna Beam Width and 10m Measurement Range from wholesalers
    • Buy cheap High Integration KLM800 Radar Level Sensor Module with ±2.75° Antenna Beam Width and 10m Measurement Range from wholesalers
    • Buy cheap High Integration KLM800 Radar Level Sensor Module with ±2.75° Antenna Beam Width and 10m Measurement Range from wholesalers
    • Buy cheap High Integration KLM800 Radar Level Sensor Module with ±2.75° Antenna Beam Width and 10m Measurement Range from wholesalers

    High Integration KLM800 Radar Level Sensor Module with ±2.75° Antenna Beam Width and 10m Measurement Range

    Ask Lasest Price
    Brand Name : KACISE
    Model Number : KLM800
    Certification : CE
    Price : 120
    Payment Terms : 100% payment in advance
    • Product Details
    • Company Profile

    High Integration KLM800 Radar Level Sensor Module with ±2.75° Antenna Beam Width and 10m Measurement Range

    Product Description:

    The millimeter wave radar component is made up of three main parts: radio frequency unit, processing unit, and printed board antenna. This type of radar has the unique ability to detect targets through various obstacles like rain, fog, or frost, making it an ideal small sensor that can run all day long. Additionally, millimeter wave radar boasts high integration, small size, and flexible interface.

    The level meter radar is based on millimeter wave radar technology and measures the height of the antenna from the liquid level. This type of radar is popularly used in water resource measurement, including in rivers, reservoirs, and tanks.

    The modules for the radar can come from a range of devices. The radar ranging module can be used in solid-state and liquid working conditions and operates with the support of an 80G high-frequency chip. The lens antenna configuration can also be adapted to different environments.

    Overall, this product is highly useful in a range of industries such as water conservancy engineering, sewage treatment plants, and petroleum chemical plants.

    Features:

    ● High integration

    ● Small volume

    ● Flexible interface

    ● It can detect targets through obstacles such as light, rain, dust, fog or frost

    ● Small sensors that work all day long


    Technical Parameters:

    Model numberKLM800_485
    Frequency of measurement80GHz
    Means of communicationRS_485
    Frequency of acquisition160 ms/configurable
    Current of operation12V 30MA
    Distance measurement accuracy±2mm
    Communication protocolmodbus
    Antenna beam width±2.75°
    Supply voltage9-24V
    Range of measurement3m;10m;20m;40m
    Dimensions of modules

    47 mm diameter

    64 mm diamete

    Working humidity0~95%
    Operating temperature-20~70℃

    Dimensions:

    High Integration KLM800 Radar Level Sensor Module with ±2.75° Antenna Beam Width and 10m Measurement Range


    High Integration KLM800 Radar Level Sensor Module with ±2.75° Antenna Beam Width and 10m Measurement RangeHigh Integration KLM800 Radar Level Sensor Module with ±2.75° Antenna Beam Width and 10m Measurement Range

    Applications:

    ● River, reservoir and other water conservancy survey

    ● Tank level and water level measurement

    ● Water conservancy project

    ● Sewage treatment plan

    ● Petroleum chemical plant


    Power supply and communication

    The module interface is shown in the following figure:

    InterfaceNameFunction
    1Download the mouthFor STLINK firmware upgrade and simulation debugging
    2Power supply port3.3 V power supply, GND
    3Serial portUsed for timing command issuance

    Equipment installation instructions

    When installing the module, try to keep it fixed to avoid module jitter and keep the surrounding environment as open as possible.

    1. The distance between the module and the water surface is higher than 30cm to ensure that the front face of the module (antenna surface) is parallel to the measuring liquid level;

    2. The distance between the module and the edge of the tank, the edge of the pool, the edge of the river dam and the edge of the pool is greater than 1 meter;

    3. choose the less volatile the location of the installation module (try not to install in the injection port and outlet undulation is big, the undulation, the greater the measurement precision, the worse).

    4. Installation diagram

    Guarantee within the scope of the beam without distractions, such as Banks of the river bank.

    Points to note

    Module installation to maintain constant as far as possible, avoid module jitter, surrounding environment to open as much as possible.

    1. The distance between the module and the water surface is higher than 30cm to ensure that the front face of the module (antenna surface) is parallel to the measuring liquid level

    2. The distance between the module and the edge of the tank, the edge of the pool, the edge of the river dam and the edge of the pool is greater than 0.5 meters;

    3. choose the less volatile the location of the installation module (try not to install in the injection port and outlet undulation is big, the undulation, the greater the accuracy of measurement, the worse))

    A serial port communication protocol

    Frame head (1B)0XFF
    Measuring dismissal (4B)Height measurement (floating-point type, in centimeters)
    Check and (1 b)The measurement result is rounded, and the high byte and low byte are summed and the low byte is taken as the checksum

    For example, the sent data is FF 2A 4B 90 42 47, where FF is the frame header, the middle 4 bytes "2A 4B 90 42" is the distance information, and the size end sets its true information to 42 90 4B 2A (hexadimal floating point type), which is converted to decimal 72.1468 cm.

    47 is a checksum, its calculation is as follows:

    First to convert floating point distance 72.1468 uint32_t integer (4 bytes) to 72, in low level in two bytes 0 (HEX 0), low of 72 (HEX 48) as the checksum as frame head low, high + + integer integer to take low 8 bits, (FF + 0 x00 + 0 x48) & 0 x47 x00ff = 0.

    Add: SScom test mode

    Can be tested using a serial port to help (hand SScom) :

    1. Use the USB serial port module connected to the computer USB interface, open SSCOM serial debugging software, choice

    The correct port;

    2.Send the AT + TLVS = 1 n, to convert the output string, according to send the command

    "AT + START n";

    3.The output string



    Note: the default baud rate to 9600. If you open a string with no right side of SSCOM, click the extension to the right of "Save Parameters" to display it.

    Common instruction specification
    AT+STARTnStart the command
    AT+RESETnReset command
    AT+BAUD=9600nBaud rate command
    AT+TIME =160nFrame cycle (that is, change the output interval)
    AT+READnCheck that the common configuration is correct
    AT+TLVS=1nChange the output (default is 0 in hexadecimal)

    Notes:

    In the working state of the MCU, to configure, first send the reset command (interrupt the work), customize the input command, then send the reset command (make the configuration effective), and send the start command.


    The MODBUS RTU communication protocol

    1.Setup instructions: function code 0 x10

    (1)Restore factory Settings

    Request command:

    Device addressFunction codeStarting addressRegister countData lengthDataCRC
    0x7F0x100x10 000x00 010x020x00 000x9E 33

    Data definition: 0 to restore the factory Settings, 1 to restart the program.

    Reply data:

    Device addressFunction codeStarting addressRegister countCRC
    0x7F0x100x10 000x00 010x0F 17

    Examples:

    Request: 7 f 10 10 00 00 02 00 00 9 e 33 01

    Reply: 7 f 10 10 00 00 0 f 17 01

    Where the data part 00 00 means to restore the factory Settings.

    (2)From the machine address

    Request command:

    Device addressFunction codeStarting addressRegister countData lengthDataCRC
    0x7F0x100x20 010x00 010x020x00 010x6E 21

    Data definition: value range 1--247.

    Reply data:

    Device addressFunction codeStarting addressRegister countCRC
    0x7F0x100x20 010x00 010x51 D7

    Examples:

    Request: 7F 10 20 01 00 01 02 00 01 6E 21

    Reply: 7 f 10 20 01 00 01 51 D7

    The data part 00 01 indicates that the slave address is set to 1.


    (3)Range of measurement

    Request command:

    Device addressFunction codeStarting addressRegister countData lengthDataCRC
    0x7F0x100x20 460x00 020x040x00 00 41 300x40 19

    Data definition: The data value is Float data, the unit is meters, the data length value is 4 bytes, the data format is low 16 bits of data in the front, high 16 bits of data in the back.

    Reply data:

    Device addressFunction codeStarting addressRegister countCRC
    0x7F0x100x20 460x00 020xA1 C3

    Examples:

    Request: 7 46 00 02 04 f 10 20 00 00 41 30 to 40 19

    Re: 7F 10 20 46 00 02 A1 C3

    00 00 41 30 into which the data portion of the floating-point data that is 11 meters.


    (4)Measure the time interval

    Request command:

    Device addressFunction codeStarting addressRegister countData lengthDataCRC
    0x7F0x100x20 2E0x00 010x020x03 E80xA8 C0

    Data definition: Set the time interval of water level meter data collection, unit ms, and the minimum value is 100ms.

    Reply data:

    Device addressFunction codeStarting addressRegister countCRC
    0x7F0x100x20 2E0x00 010x60 1E

    Examples:

    Request: 7 2 e f 10 20 00 02 03 01 E8 A8 C0

    Reply: 7F 10 20 2E 00 01 60 1E

    Among them, the data part 03 E8 is converted to decimal 1000, that is, the data acquisition interval is set to 1000ms.


    (5)Communication baud rate

    Request command:

    Device addressFunction codeStarting addressRegister countData lengthDataCRC
    0x7F0x100x20 020x00 010x020x25 800xB4 E2

    Data definition: Communication baud rate: 4800,9600,19200.


    Reply data:

    Device addressFunction codeStarting addressRegister countCRC
    0x7F0x100x20 020x00 010xA1 D7

    Examples:

    Request: 7 f 10 20 00 02 01, 02, 25 80 B4 E2

    Reply: 7F 10 20 02 00 01 A1 D7

    The data part 28 80 means that the communication baud rate is set to 9600.


    2.Query instruction: Function code 0x03

    (1)From the machine address

    Request command:

    Device addressFunction codeStarting addressRegister countCRC
    0x7F0x030x20 010x00 010xD4 14

    Reply data:

    Device addressFunction codeData lengthDataCRC
    0x7F0x030x020x00 010x51 8E

    Data definition: value range 1--247.

    Examples:

    Request: 7 f 03 01 00 20 01 D4 14

    Reply: 7 f 03 02 0 01 51 8 e

    The data part 00 01 means that the slave address is 1.


    (2)Range ability

    Request command:

    Device addressFunction codeStarting addressRegister countCRC
    0x7F0x030x20 460x00 020x24 00

    Reply data:

    Device addressFunction codeData lengthDataCRC
    0x7F0x030x040x00 00 41 300x54 70

    Data definition: The data value is Float data, the unit is meters, the data length value is 4 bytes, the data format is low 16 bits of data in the front, high 16 bits of data in the back.

    Examples:

    Request: 7 46 f 03 20 00 00 02 24

    Reply: 7 f 03 04 00 00 41 30 54, 70

    The data part 00 00 41 30 is converted to floating point data, which is 11 meters.


    (3) Baud rate of communication

    Request command:

    Device addressFunction codeStarting addressRegister countCRC
    0x7F0x030x20 020x00 010x24 14

    Reply data:

    Device addressFunction codeData lengthDataCRC
    0x7F0x030x020x28 800x8D 7E

    Examples:

    Request: 7 f 20 00 02 03 01 24 14

    Re: 7F 03 02 25 80 8B 7E

    The data part 28 80 means the communication baud rate is 9600.


    (4)Measure the time interval

    Request command:

    Device addressFunction codeStarting addressRegister countCRC
    0x7F0x030x20 2E0x00 010xE5 D0

    Reply data:

    Device addressFunction codeData lengthDataCRC
    0x7F0x030x020x03 E80x90 F0

    Data definition: Set the time interval of water level meter data collection, unit ms, and the minimum value is 100ms.

    Examples:

    Request: 7F 03 20 2E 00 01 EF C3

    Reply: 7 f 03 02 90 F0 03 E8

    Among them, the data part 03 E8 was converted to decimal 1000, indicating that the data acquisition interval was 1000ms.

    (5)Query measurement results

    Request command:

    Device addressFunction codeStarting addressRegister countCRC
    0x7F0x040x0A 0F0x00 020x48 0E

    Reply data:

    Device addressFunction codeData lengthDataCRC
    0x7F0x040x040x04 19 3F 9E0x25 2C

    Data Definition: Data value is Float type data, the unit is meters. Data length value is 4 bytes, data format for the low 16 bits of data in the former, high 16 bit data behind. The meaning of the measurement result is associated with the type of measurement, and the default is the water level.

    Examples:

    Request: 7 4 0 f a 48 0 0 f 00 02 e

    Reply: 7 f 04 04 04 19 3 f 9 e 25 2 c

    The data part 04 19 3F 9E is converted to floating point data that is 1.2345 meters.

    19049 e3f, in one place, with right high position.

    (6)Query version

    Request command:

    Device addressFunction codeStarting addressRegister countCRC
    0x7F0x030x20 040x00 020x48 14

    Reply data:

    Device addressFunction codeData lengthDataCRC
    0x7F0x030x040x20 23 05 120x1D 63

    Data definition: The data is in BCD encoding format, 0x20 0x23 0x05 0x12, which means data 20230512.

    (7)Broadcast address query devices

    Request command:

    Device addressFunction codeStarting addressRegister countCRC
    0xFF0x030x20 010x00 010xCB D4

    Reply data:

    Device addressFunction codeData lengthDataCRC
    0x7F0x030x020x00 7F0xD1 AE

    Data definition: 0x7F in the data is the 485 address of the device.


    Support and Services:

    Our Accelerometer Sensor product technical support and services include:

    • Assistance with installation and setup
    • Troubleshooting and diagnostics
    • Repair and replacement services
    • Technical documentation and resources

    Packing and Shipping:

    Product Packaging:

    The accelerometer sensor will be packaged in a sturdy cardboard box with cushioning material to prevent damage during transit. The box will also be labeled with the product name and any necessary handling instructions.

    Shipping:

    The product will be shipped via standard ground shipping unless expedited shipping is requested and paid for by the customer. Shipping costs will be calculated based on the destination and weight of the package. Customers will receive a tracking number once the package has been shipped.

    Quality High Integration KLM800 Radar Level Sensor Module with ±2.75° Antenna Beam Width and 10m Measurement Range for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)