Sign In | Join Free | My burrillandco.com
Home > Fluid Level Meter >

KDI Series Display Controller with Multi-Machine Communication RS-485 Interface and Digital Auto-Tuning

    Buy cheap KDI Series Display Controller with Multi-Machine Communication RS-485 Interface and Digital Auto-Tuning from wholesalers
     
    Buy cheap KDI Series Display Controller with Multi-Machine Communication RS-485 Interface and Digital Auto-Tuning from wholesalers
    • Buy cheap KDI Series Display Controller with Multi-Machine Communication RS-485 Interface and Digital Auto-Tuning from wholesalers
    • Buy cheap KDI Series Display Controller with Multi-Machine Communication RS-485 Interface and Digital Auto-Tuning from wholesalers
    • Buy cheap KDI Series Display Controller with Multi-Machine Communication RS-485 Interface and Digital Auto-Tuning from wholesalers

    KDI Series Display Controller with Multi-Machine Communication RS-485 Interface and Digital Auto-Tuning

    Ask Lasest Price
    Brand Name : KACISE
    Model Number : KDI Series
    Certification : CE
    Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
    Supply Ability : 1000 Piece/Pieces per Week negotiable
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    KDI Series Display Controller with Multi-Machine Communication RS-485 Interface and Digital Auto-Tuning

    KDI Series Display Controller Supporting Multi - machine Communication
    Introduction

    KACISE's KDI Series Display Controller supports multi - machine communication. It offers a variety of standard serial two - way communication functions, such as RS - 232C, RS - 485, and RS - 422. The communication baud rate can be freely set from 300 to 9600bps. It can communicate with devices like computers, programmable controllers, and PLCs, forming intelligent management systems. KACISE's focus on quality ensures stable and efficient communication in different scenarios.

    Features
    • New concept of computer digital auto-tuning
    • Clear and clear measurement display
    • Support multi-machine network communication, communication protocol can be freely set
    • Unique full open user-defined interface
    • Set parameter power-off permanent retention and parameter password lock
    • Fully digital cold junction compensation
    • Multi-size external structure size
    • AC and DC switching power supply mode
    Parameters
    Matching with standard indexing temperature sensor:
    Input SignalIndexing No.ResolutionSensorRange
    B1Platinum30-platinum6 rhodium400~1800℃
    S1Platinum10-platinum0~1600℃
    K1Nickel chromium-nickel silicon0~1300℃
    E1Nickel chromium-constantan0~1000℃
    J1Iron-constantan0~1200℃
    T0.1Copper-constantan-199.9~3200℃
    Wre1Tungsten3-tungsten250~2300℃
    Pt1001Platinum thermal resistance R0 = 100Ω-199~650℃
    Pt1000.1Platinum thermal resistance R0= 100Ω-199.9~320.0℃
    Cu500.1Copper thermal resistance R0= 50Ω-50.0~150.0℃
    With standard signal transmitter:
    Input SignalStandard Signal RangeInput ResistanceMatching TransmitterMeasuring Range

    various mV signal

    0~10mA

    4~20mA

    0~5V

    1~5V

    30~350Ω

    ≥10MΩ

    ≤250Ω

    ≤250Ω

    ≥250KΩ

    ≥250KΩ

    hall transmitter

    compatible with DDZ-II type instrument

    compatible with DDZ-III type instrument

    compatible with DDZ-II type instrument

    compatible with DDZ-III type instrument

    compatible with remote pressure resistors

    set according to user needs.

    range:

    -1999~9999

    Main Technical parameters
    Input SignalAnalog

    Resistance: standard thermal resistance (remote pressure resistance such as Pt100, Cu50)

    Galvanic couples: standard thermocouples ( B, S, K, E, J, T, WRe, etc.)

    Current: 0~10mA, 4~20mA, 0~20mA, etc. (Input impedance ≤250Ω)

    Voltage: 0~5V, 1~5V, etc.(Input impedance ≥250Ω)

    Measuring Range-1999~9999
    Accuracy0.2% FS ±1 or 0.5% FS ±1
    Resolution1, 0.1, 0.01 or 0.001
    Temperature Compensation0~50
    Display Method

    -19999~9999 measured value display

    -19999~9999 set value display

    0~100% measured value light column display

    LED operating status display

    Light Column AccuracyThe light column display accuracy is 1%
    Control MethodPosition ON / OFF with backlash
    Output SignalAnalog output

    DC 0-5V (load capacity ≤250Ω)

    DC 1~5V (load capacity ≤250Ω)

    DC 0~10mA (load capacity ≤750Ω)

    DC 4~20mA (load capacity ≤500Ω)

    Switch output

    Relay control output - Relay ON/OFF with backlash

    Contact capacity: AC220V/3A; DC24V/6A (resistive load)

    Controllable silicon output-SCR (controllable zero-crossing pulse), can trigger controllable silicon: 400V/100A

    Solid state relay output - SSR (solid state relay control signal) output, 6 ~ 24 / 30mA (voltage cannot be adjusted)

    Communication outputInterface mode - Standard serial two-way communication interface: RS-485, RS-232C, RS-422, etc.
    Feed outputDC24V, load capacity ≤30mA
    control method

    Optional 1~4 limit control, LED indication. The control mode is the relay ON/OFF with backlash (user can set it freely)

    control accuracy±1
    Alarm modeYou can select 1~4 limit alarm, LED indication. The control mode is the relay ON/OFF with backlash (user can set it freely)
    Alarm accuracy±1
    Temperature compensation0~5 0°C digital temperature automatic compensation
    Parameter setting

    • Panel touch type press key digital setting

    • Parameter setting value is permanently hold when power off

    • Parameter setting value Password Lock

    Protection method

    • Input loop disconnection alarm (when thermocouple or resistance input), relay output, LED indication

    • Input over/under range alarm

    • Power under voltage automatic reset

    •Work abnormally automatic reset (watch dog)

    Online communicationThe communication protocol is a two-wire system, a three-wire system or a four-wire system (e.g. RS485, RS232C, RS422, etc. ) can also be specially requested by the user. The baud rate of 300 to 9 6 0 0 b p s can be set freely by the internal parameters of the instrument. The interface and the main unit are separated by photo-electricity, and the communication distance can reach 1.2 km. The system adopts the master-slave communication mode. The whole control loop only needs one two (three, four) core cable, which can realize communication with the host computer. The upper computer can call the device number set by the user, and call the scene of each instrument at any time. Data, and can be used to set internal parameters of the instrument. Equipped with data collector and industrial control software, it can realize online communication between multiple instruments and one or more microcomputers.
    Use environment

    • Ambient temperature 0~5 0°C

    • Relative humidity ≤ 85 R H

    • Avoid strong corrosive gases

    Power Supply

    Normal type :

    • A C 220 V + 10 - 1 5 % (50 Hz ± 2Hz linear power source )

    Special type:

    • A C 90 ~ 260 V- - switch power

    • D C 24 V ±2 V- - switch-off power supply

    Power consumption

    • ≤5 W (A C 220 V linear power supply)

    • ≤4 W (A C 90 V~265 V switch power supply)

    • ≤4 W (D C 4 V power supply)

    Weight420g (AC220V linear power supply)
    Product Tags:

    KDI Series Display Controller

      
    Quality KDI Series Display Controller with Multi-Machine Communication RS-485 Interface and Digital Auto-Tuning for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)